Background:The purpose of this study was to compare the effectiveness of different ultrasonic scalers and a periodontal curette on the root surfaces for calculus removal and root surface roughness.Materials and Methods:40 single rooted teeth with subgingival calculus destined for extraction were assigned to one of three experimental groups (n = 10, in each group) and one control group (untreated, n = 10). Experimental groups were: Group 1: Piezoelectric ultrasonic group; Group 2: Magnetostrictive ultrasonic group; Group 3: Hand instrumentation group (Curette). After instrumentation, the teeth were extracted and the presence of residual deposits and root surface roughness were analyzed using Planimetric analyzing tool (Tool that measures the area of a plane figure as a mechanically coupled pointer traversing the perimeter of figure) and Surface Profilometer (Instrument used for profiling of an object). Root surface characteristics were evaluated qualitatively using SEM. Standardization of force, angulations and adaptation of instrument couldn’t be achieved in our study due to in vivo study design rather than in vitro design in previous studies where procedure was done on the extracted teeth samples.Results:The results of the study showed that residual deposits were similar in all experimental groups. With respect to roughness parameters, Rq (Root mean square roughness) and Rt (Total roughness) a significant difference was observed (P < 0.001) among hand instrumentation and ultrasonic devices. SEM analysis revealed a similar root surface pattern for the ultrasonic devices, but curette showed many instrument scratches, gouges, and removal of large amount of cementum.Conclusions:Curette produced the rougher root surfaces than two ultrasonic devices used in the study and caused more root surface removal. Piezoelectric devices produced minimum root surface roughness but caused more root substance removal and more cracks than Magnetostrictive ultrasonic devices.
According to the results of this study, PB affected the heights and presence of maxillary interdental papillae by affecting papilla proportion and distances between the facial and palatal papillae.
Aim: The aim of the study was to quantify the specific spatial displacement of gingival zenith (GZ) and determine a representative value for the interdental papilla height as a percentage ratio of clinical crown length (CL), as measured from GZ in the maxillary anterior dentition. Materials and methods: A total of 100 subjects and 1,200 interdental papillae were included. Eighty percent of the population presented with the gingival margin of lateral incisor (LI) teeth positioned coronally to the GZ of the ipsilateral canine (C) and central incisor (CI). Results: No significant difference was found between mesial and distal papilla proportion (DPP) of maxillary incisor groups. In the C group, numerical values showed higher DPP. Conclusion: The data achieved provide the ideal numerical values for prosthetic, restorative, periodontal, implant, postorthodontic, and esthetic treatment outcomes. Clinical significance: The study describes the importance of quantifying the ideal numerical values for prosthetic, restorative, periodontal, implant, postorthodontic, and esthetic treatment outcomes. The readers should understand to quantify the specific spatial displacement of GZ and determine a representative value for the interdental papilla height as a percentage ratio of clinical CL, as measured from GZ in the maxillary anterior dentition.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.