This work presents a rapid, highly sensitive, low-cost, and specific capacitive DNA sensor for detection of whole genome human herpesvirus-1 DNA. This sensor is capable of direct DNA detection with a response time of 30 s, and it can be used to test standard buffer or serum samples. The sensing approach for DNA detection is based on alternating current (AC) electrokinetics. By applying an inhomogeneous AC electric field on sensor electrodes, positive dielectrophoresis is induced to accelerate DNA hybridization. The same applied AC signal also directly measures the hybridization of target with the probe on the sensor surface. Experiments are conducted to optimize the AC signal, as well as the buffers for probe immobilization and target DNA hybridization. The assay is highly sensitive and specific, with no response to human herpesvirus-2 DNA at 5 ng/mL and a LOD of 1.0 pg/mL (6.5 copies/μL or 10.7 aM) in standard buffer. When testing the double stranded (ds) DNA spiked in human serum samples, the sensor yields a LOD of 20.0 pg/mL (129.5 copies/μL or 0.21 femtomolar (fM)) in neat serum. In this work, the target is whole genome dsDNA, consequently the test can be performed without the use of enzyme or amplification, which considerably simplifies the sensor operation and is highly suitable for point of care disease diagnosis.
A sensitive and efficient method for microRNAs (miRNAs) detection is strongly desired by clinicians and, in recent years, the search for such a method has drawn much attention. There has been significant interest in using miRNA as biomarkers for multiple diseases and conditions in clinical diagnostics. Presently, most miRNA detection methods suffer from drawbacks, e.g., low sensitivity, long assay time, expensive equipment, trained personnel, or unsuitability for point-of-care. New methodologies are needed to overcome these limitations to allow rapid, sensitive, low-cost, easy-to-use, and portable methods for miRNA detection at the point of care. In this work, to overcome these shortcomings, we integrated capacitive sensing and alternating current electrokinetic effects to detect specific miRNA-16b molecules, as a model, with the limit of detection reaching 1.0 femto molar (fM) levels. The specificity of the sensor was verified by testing miRNA-25, which has the same length as miRNA-16b. The sensor we developed demonstrated significant improvements in sensitivity, response time and cost over other miRNA detection methods, and has application potential at point-of-care.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.