Sonography is commonly used for diagnosis of desmopathy of the proximal part of the suspensory ligament in horses. However, magnetic resonance (MR) imaging has been stated to be superior for detecting disease and localizing lesions. In this retrospective study of 39 horses or 46 hind limbs with lameness due to proximal plantar metatarsal pain, the clinical and diagnostic findings are discussed and sonography and MR imaging compared for examination of the proximal part of the suspensory ligament. With MR imaging interpreted as the clinical gold standard, desmopathy of the proximal part of the suspensory ligament was diagnosed in 21 hind limbs, proximal plantar metatarsal pain of unknown cause in 12, an osseous injury at the origin of the suspensory ligament in four and a condition unrelated to the suspensory ligament in nine. Based on these findings, sonography had a sensitivity of 0.77 and 0.66 and specificity of 0.33 and 0.31 for diagnosing proximal suspensory desmopathy and for accurately localizing lesions, respectively. MR imaging changes consistent with proximal suspensory desmopathy were signal hyperintensities and an increase in cross-sectional area compared with the contralateral limb. Anesthesia of the deep branch of the lateral plantar nerve is not specific neither for proximal suspensory desmopathy, as conditions unrelated to the suspensory ligament were diagnosed, nor for diagnosis of proximal plantar metatarsal pain, as conditions outside the proximal plantar metatarsal region were also diagnosed.
Tendon injuries are common in athletic humans and horses. Ultrasonography is the diagnostic method of choice in horses with tendon injuries but there is increasing application of magnetic resonance (MR) imaging to monitor and follow-up tendon healing. A core lesion was created in the superficial digital flexor tendon (SDFT) of each forelimb of four horses. One of the four horses was euthanized at 2, 4, 8, and 12 weeks after creation of the lesion. MR examinations of the SDFT were performed immediately post mortem in a 1.5 T Siemens Symphony magnet and compared with histologic findings. Measurements from the MR images were also compared to ultrasonographic measurements available from the same lesions. Tendon lesions appeared as well-circumscribed hyperintensities in the core of the SDFT on all pulse sequences. Lesions were most conspicuous on fat-suppressed fast low angle shot (FLASH) sequences and least conspicuous on T2 transverse dual turbo spin echo (T2 TSE) sequences. The signal-difference-to-noise ratio decreased with the age of the lesion in all sequences in this study. Twelve-week-old lesions were not visible on T2 TSE images but in all other sequences the lesion remained hyperintense. The lesion volume and maximum cross-sectional area of core lesions were significantly smaller in T2 TSE images than in other MR sequences. The lesion volume and maximum cross-sectional area of core lesions were significantly larger in proton density, T1, and FLASH sequences and significantly smaller in T2 sequences than when measured from ultrasonographic images. Through comparison between sequences, MR imaging may be able to provide information on various stages of tendon healing.
Tendon and ligament injuries are common causes of impaired performance in equine athletes. Gray-scale ultrasonography is the current standard method for diagnosing and monitoring these injuries, however this modality only provides morphologic information. Elastography is an ultrasound technique that allows detection and measurement of tissue strain, and may provide valuable mechanical information about equine tendon and ligament injuries. The purpose of this study was to determine the feasibility, reproducibility, and repeatability of elastography; and to describe elastographic characteristics of metacarpal tendons in sound horses. Nineteen legs for 17 clinically sound horses without evidence of musculoskeletal pathology were included. Elastographic images of the superficial and deep digital flexor tendons and the branches of the suspensory ligament (tendon of the interosseous muscle) were described quantitatively and qualitatively. There was no statistically significant difference between operators (P = 0.86) nor within operators (P = 0.93). For qualitative assessments, reproducibility (0.46) was moderate and repeatability (0.78) was good. Similar to human Achilles tendons, equine tendons were classified as predominantly hard using elastography. There was no statistically significant difference in stiffness of the flexor tendons (P = 0.96). No significant difference in stiffness was found with altered leg position during standing (P = 0.84) and while nonweight bearing (P = 0.61). The flexor tendons were softer when imaged in longitudinal versus transverse planes (P < 0.01) however, the suspensory branches were not (P = 0.67). Findings supported future clinical application of elastography as a noninvasive "stall-side" imaging modality for evaluation of the tendons and ligaments of the distal forelimb in horses.
Osteoarthritis of the distal tarsal joints, affecting the centrodistal and tarsometatarsal joints, is a common cause of hindlimb lameness in horses. This paper describes the outcome of the intra-articular treatment of 51 horses with the condition with either methylprednisolone acetate (mpa) or triamcinolone acetonide (tr), either with or without hyaluronic acid (ha). The outcome was assessed in terms of the changes in the horses' grade of lameness. Follow-up information was obtained from the owners by means of a telephone questionnaire. Horses treated once with mpa or tr, either with or without ha, improved after a median of 56 days (P<0.0001), and there was no significant difference between mpa and tr. There was no significant further improvement in the horses treated twice. In the horses in which there was a diffuse increase in the uptake of a radiopharmaceutical by the distal tarsal joints, identified by scintigraphy, the lameness tended to improve (P=0.032), whereas in the horses in which the uptake was focal, it did not. At telephone follow-up 13 of 34 horses were reported to have had a positive outcome, but the outcome in the other 21 was reported to have been negative.
Objective To assess fracture gap reduction and stability of linear vs triangular 4.5‐mm lag screw repair of experimental, uniarticular, and complete forelimb proximal phalanx (P1) fractures. Study design Experimental. Sample population Fourteen equine cadaver limbs/horses. Methods Simulated fractures were repaired with 2 lag screws under 4‐Nm insertion torque (linear repair). Computed tomography (CT) imaging was performed with the leg unloaded and loaded to forces generated while walking. The fracture repair was revised to include 3 lag screws placed with the same insertion torque (triangular repair) prior to CT. The width of the fracture gap was assessed qualitatively by 2 observers and graded on the basis of gap measurements relative to the average voxel size at dorsal, mid, and palmar P1 sites. Interobserver agreement was assessed with Cohen's κ. The effect of repair type, loading condition, and measurement site on fracture gap grades was evaluated by using Kendall's τ‐b correlation coefficients and paired nonparametric tests. Significance was set at P ≤ .05. Results Agreement between loading and fracture gap widening was fair in triangular (κ = 0.53) and excellent in linear (κ = 0.81) repairs. Loading resulted in fracture gap distraction in linear repairs (Plinear = .008). Triangular repairs reduced fractures better irrespective of loading (Punloaded = .003; Ploaded < .001). The type of repair was not correlated with fracture gap grades at unloaded mid and loaded dorsal P1 sites. Conclusion Repair of uniarticular complete parasagittal fractures with a triangular screw configuration improved in vitro fracture gap reduction and stability. Clinical significance Triangular lag screw repair likely improves biomechanical conditions during postoperative weight bearing.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.