Blue (T-1824) was injected into the right ventricle through a cardiac catheter and the time of the arrival of dye at the ear was measured with an oximeter. This circulation time appeared to indicate reliably the presence of venoarterial shunting through an over-riding aorta. The difficulties ordinarily encountered in positive identification of this defect are discussed. The importance of the identification, particularly with regard to the differential diagnosis between tetralogy of Fallot and pulmonary stenosis with an interatrial communication, is stressed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.