SummaryBackgroundMagnetic resonance enterography (MRE) and ultrasound are used to image Crohn's disease, but their comparative accuracy for assessing disease extent and activity is not known with certainty. Therefore, we did a multicentre trial to address this issue.MethodsWe recruited patients from eight UK hospitals. Eligible patients were 16 years or older, with newly diagnosed Crohn's disease or with established disease and suspected relapse. Consecutive patients had MRE and ultrasound in addition to standard investigations. Discrepancy between MRE and ultrasound for the presence of small bowel disease triggered an additional investigation, if not already available. The primary outcome was difference in per-patient sensitivity for small bowel disease extent (correct identification and segmental localisation) against a construct reference standard (panel diagnosis). This trial is registered with the International Standard Randomised Controlled Trial, number ISRCTN03982913, and has been completed.Findings284 patients completed the trial (133 in the newly diagnosed group, 151 in the relapse group). Based on the reference standard, 233 (82%) patients had small bowel Crohn's disease. The sensitivity of MRE for small bowel disease extent (80% [95% CI 72–86]) and presence (97% [91–99]) were significantly greater than that of ultrasound (70% [62–78] for disease extent, 92% [84–96] for disease presence); a 10% (95% CI 1–18; p=0·027) difference for extent, and 5% (1–9; p=0·025) difference for presence. The specificity of MRE for small bowel disease extent (95% [85–98]) was significantly greater than that of ultrasound (81% [64–91]); a difference of 14% (1–27; p=0·039). The specificity for small bowel disease presence was 96% (95% CI 86–99) with MRE and 84% (65–94) with ultrasound (difference 12% [0–25]; p=0·054). There were no serious adverse events.InterpretationBoth MRE and ultrasound have high sensitivity for detecting small bowel disease presence and both are valid first-line investigations, and viable alternatives to ileocolonoscopy. However, in a national health service setting, MRE is generally the preferred radiological investigation when available because its sensitivity and specificity exceed ultrasound significantly.FundingNational Institute of Health and Research Health Technology Assessment.
Increasing mural thickness, high mural signal intensity on T2-weighted fat-saturated images, and a layered pattern of enhancement reflect histologic features of acute small-bowel inflammation in Crohn disease.
Magnetic resonance (MR) enterography is a clinically useful technique for the evaluation of both intraluminal and extraluminal small bowel disease, particularly in younger patients with Crohn disease. MR enterography offers the advantages of multiplanar capability and lack of ionizing radiation. It allows evaluation of bowel wall contrast enhancement, wall thickening, and edema, findings useful for the assessment of Crohn disease activity. MR enterography can also depict other pathologic findings such as lymphadenopathy, fistula and sinus formation, abscesses, and abnormal fold patterns. Even subtle disease manifestations may be detected when adequate distention of the small bowel is achieved, although endoscopic and double-contrast barium small bowel techniques remain superior in the depiction of changes in early Crohn disease (eg, aphthoid ulceration). Further research will be needed to determine whether MR imaging enhancement patterns may reliably help discriminate between active and inactive disease.
To establish the optimum barium-based reduced-laxative tagging regimen prior to CT colonography (CTC). Ninety-five subjects underwent reduced-laxative (13 g senna/18 g magnesium citrate) CTC prior to same-day colonoscopy and were randomised to one of four tagging regimens using 20 ml 40%w/v barium sulphate: regimen A: four doses, B: three doses, C: three doses plus 220 ml 2.1% barium sulphate, or D: three doses plus 15 ml diatriazoate megluamine. Patient experience was assessed immediately after CTC and 1 week later. Two radiologists graded residual stool (1: none/scattered to 4: >50% circumference) and tagging efficacy for stool (1: untagged to 5: 100% tagged) and fluid (1: untagged, 2: layered, 3: tagged), noting the HU of tagged fluid. Preparation was good (76-94% segments graded 1), although best for regimen D (P=0.02). Across all regimens, stool tagging quality was high (mean 3.7-4.5) and not significantly different among regimens. The HU of layered tagged fluid was higher for regimens C/D than A/B (P=0.002). Detection of cancer (n=2), polyps ≥6 mm (n=21), and≤5 mm (n=72) was 100, 81 and 32% respectively, with only four false positives ≥6 mm. Reduced preparation was tolerated better than full endoscopic preparation by 61%. Reducedlaxative CTC with three doses of 20 ml 40% barium sulphate is as effective as more complex regimens, retaining adequate diagnostic accuracy.
Certain MR imaging-derived mural hemodynamic parameters correlate with disease chronicity and angiogenesis in Crohn disease, but not with histologic and clinical markers of inflammation. Data support the working hypothesis that microvessel permeability increases with disease chronicity and that tissue MVD is actually inversely related to mural blood flow.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.