Silica glass is frequently used as a device material for micro/nano fluidic devices due to its excellent properties, such as transparency and chemical resistance. Wet etching by hydrofluoric acid and dry etching by neutral loop discharge (NLD) plasma etching are currently used to micromachine glass to form micro/nano fluidic channels. Electro-osmotic flow (EOF) is one of the most effective methods to drive liquids into the channels. EOF mobility is affected by a property of the micromachined glass surfaces, which includes surface roughness that is determined by the manufacturing processes. In this paper, we investigate the effect of micromaching processes on the glass surface topography and the EOF mobility. We prepared glass surfaces by either wet etching or by NLD plasma etching, investigated the surface topography using atomic force microscopy, and attempted to correlate it with EOF generated in the micro-channels of the machined glass. Experiments revealed that the EOF mobility strongly depends on the surface roughness, and therefore upon the fabrication process used. A particularly strong dependency was observed when the surface roughness was on the order of the electric double layer thickness or below. We believe that the correlation described in this paper can be of great help in the design of micro/nano fluidic devices.
The present study proposes a non-intrusive visualization technique based on two-wavelength Raman imaging for in-situ monitoring of the unsteady temperature field in microfluidic systems. The measurement principle relies on the contrasting temperature dependencies of hydrogen-bonded and non-hydrogen-bonded OH stretching modes of the water Raman band, whose intensities were simultaneously captured by two cameras equipped with corresponding bandpass filters. The temperature distributions were then determined from the intensity ratio of the simultaneously-obtained Raman images, which enables compensation for temporal fluctuation and spatial inhomogeneity of the excitation laser intensity. A calibration experiment exhibited a linear relationship between the temperature and the intensity ratio in the range 293–343 K and least-regression analysis gave an uncertainty of 1.43 K at 95% confidence level. By applying the calibration data, time series temperature distributions were quantitatively visualized in a Y-shaped milli-channel at a spatial resolution of 6.0 × 6.0 µm2 with an acquisition time of 16.5 s. The measurement result clearly exhibited the temporal evolution of the temperature field and was compared with the values obtained by thermocouples. This paper therefore demonstrates the viability of employing the two-wavelength Raman imaging technique for temperature measurements in microfluidic devices.
This study describes the development of a noncontact and two-dimensional fluid viscosity measurement technique based on fluorescence polarization microscopy. This technique exploits fluorescence depolarization due to rotational Brownian motion of fluorophores and determines fluid viscosity in microchannel flow by measuring steady-state fluorescence polarization. The main advantage of the technique is that planar distributions of fluid viscosity can be visualized by noncontact optical measurement, while commonly-used mechanical viscometers measure the viscosity of bulk liquids. Moreover, steady-state polarization measurements are realized using a simpler experimental setup compared to other noncontact techniques such as time-resolved fluorescence lifetime/polarization measurements. The relationship between the fluid viscosity (µ) and the fluorescence polarization degree (P) was experimentally obtained using casein molecules labeled with fluorescein isothiocyanate as a fluorescent probe. The fluid viscosity was controlled within the range of 0.7-3.0 mPa s, which is the range often encountered in biological materials, by mixing sucrose or glucose with the solution. The fluid temperature was maintained uniform at 30 • C during the measurement. The calibration result showed that 1/P linearly increased with 1/µ which qualitatively agreed well with the theoretical prediction. The measurement uncertainty was 7.5%-9.5% based on the slope of the calibration curve. The viscosity gradient generated by the mass diffusion between the two solutions co-flowing in the Y-shaped microchannel was clearly visualized under uniform temperature conditions by applying the calibration curve. Finally, the influence of the temperature change on P was experimentally evaluated. The results supported the applicability of the present technique for visualization of the viscosity distribution induced by temperature change. These results confirmed the feasibility of the present technique for analyzing microscale viscosity fields associated with mass transport or temperature change.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.