Robotically assisted partial glossectomy feasibly can be performed without the need for tracheotomy. This technique resulted in greater AHI reduction but increased morbidity compared with the other techniques studied.
Custom-fit devices achieve higher rates of objective improvement and cure of OSAHS than TPD at the time of titration-PSG. TPDs have a high acceptance rate, low cost, and reasonable initial improvement and cure rates of 77.2% and 52.0%, respectively, but significantly poorer 6-month compliance.
Forty three patients with reflux oesophagitis were studied to investigate the effect of healing on oesophageal function. All patients underwent oesophageal manometry and transit studies before and after complete healing of oesophagitis. Oesophagitis was treated with omeprazole 40 mg/day for a median duration of 12 weeks. Twenty three patients also had an acid clearance test before and after healing.
Our findings show that in our population of otolaryngology patients, the diagnosis of LPR cannot be reliably made on the basis of symptoms alone. Diagnosis, and in particular treatment decisions, should ideally be made on the basis of a combination of symptoms, signs, and confirmatory testing.
For oesophageal pH monitoring, the pH probe is usually positioned 5 cm above the lower oesophageal sphincter (LOS). This is by convention, and has not been compared with other positions in its ability to discriminate between physiological and abnormal acid reflux. Using simultaneous two level 24 hour pH monitoring (5 and 10 cm above manometrically determined LOS) in 31 controls and 51 patients with reflux oesophagitis, the significance of the precise position ofthe probe in the oesophagus was examined. Secondly, this study compared the discrimination between the two groups achieved at the two levels. Patients had greater acid exposure than controls at both levels. In controls, acid exposure was greater at distal than at the proximal level except the supine acid exposure, which was similar at both levels. In patients, acid exposure was greater at the distal level for all variables (median % of total time pH <4=11-7 v 7-6; p=0001). There was excellent correlation between the two levels for all variables in controls (r=0-883, 0935, 0-813, and p<0001 for percentage of time pH <4 for total, supine, and upright times) as well as in patients (r=0-848, 0-848, 0 779, and p<0001). On discriminant and receiver operating characteristic analysis, pH threshold 4 seemed as good as or better than other pH thresholds in discriminating between controls and patients. The percentage of total time pH below 4 seemed to discriminate as well or better than other variables at both levels. The distal level (5 cm above LOS) provided slightly better discrimination than proximal level (10 cm) (percentage of subjects correctly classified=81-7 v 75.6). The critical factor for the reliability of the test is not the precise position of the pH probe relative to the LOS, but that the same position is consistently used in patients and controls.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.