The non-invasively measured initial systolic time interval (ISTI) reflects a time difference between the electrical and pumping activity of the heart and depends on cardiac preload, afterload, autonomic nervous control and training level. However, the duration of the ISTI has not yet been compared to other time markers of the heart cycle. The present study gauges the duration of the ISTI by comparing the end point of this interval, the C-point, with heart cycle markers obtained by echocardiography. The heart rate of 16 healthy subjects was varied by means of an exercise stimulus. It was found that the C-point, and therefore the end point of ISTI, occurred around the moment of the maximum diameter of the aortic arch in all subjects and at all heart rates. However, while the time difference between the opening of the aortic valves and the maximum diameter of the aortic arch decreased significantly with decreasing RR-interval, the time difference with respect to the moment of the C-point remained constant within the subjects. This means that the shortening of the ISTI with increasing heart rate in response to an exercise stimulus was caused by a shortening of the pre-ejection period (PEP). It is concluded that the ISTI can be used as a non-invasive parameter indicating the time difference between the electrical and mechanical pumping activity of the heart, both inside and outside the clinic.
Ultrasound image degradation originates primarily from transducer defects and potentially undermines reliable image interpretation. Systematic quantitative quality control is often neglected due to the limited resources available for this task. We propose a quantitative quality control based on in-air reverberation images. These images serve as an initial indication of image degradation. They are easily generated for any (curvi-)linear transducer independent of the level of expertise of the operator. Automated analysis is presented to extract quality parameters based on the in-air reverberation pattern. Static images acquired by the clinical user are transferred to a server where analysis is performed. The results are available to the sonographer prior to clinical use and transducer status can be remotely monitored with trend analysis over time. The method was evaluated for normal functioning and defect transducers. A pilot study was performed over a period of three weeks to assess reproducibility and practical feasibility. All reverberation images were successfully analysed for different transducer types and vendor-specific image presentation. The proposed quality parameters are sensitive to signal loss and allow differentiation of type and severity of image degradation. The pilot study was well received by the sonographers for the simplicity of the method and the measurements were consistent over time. The proposed automated analysis method of ultrasound quality control can monitor (curvi-)linear transducer status in the entire hospital, overcoming previous limitations for periodic quality control. Implementation of the method can reduce the number of defective transducers routinely used in clinical practice.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.