In vitro tensile bond strengths were determined for three adhesive cements and two resin-bonded bridge cements to two alloys, each prepared by two methods: sandblasted Ni-Cr-Be alloy (I), electro-etched Ni-Cr-Be alloy (II), sandblasted Type IV gold alloy (III), and tin-plated Type IV gold alloy (IV). Storage conditions of 24 hours at 37 degrees C and 30 days at 70 degrees C were evaluated. The highest bond strengths were obtained for the electro-etched Ni-Cr-Be alloy, and all bond failures were cohesive. At both 24 hours and 30 days, the adhesive cements had the highest bond strengths to the other alloy/surface preparations (I, III, and IV). The adhesive cements usually failed cohesively under these conditions, whereas the resin-bonded bridge cements failed adhesively at the cement-alloy interface. Storage for 30 days at 70 degrees C caused average decreases of 30%, 5%, 15%, and 32% for alloy/surface preparations I to IV, respectively.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.