In this paper, we demonstrated for the first time the use of electrodeposited superhydrophobic conducting polythiophene coating to effectively protect the underlying steel substrate from corrosion attack: by first preventing water from being absorbed onto the coating, thus preventing the corrosive chemicals and corrosion products from diffusing through the coating, and second by causing an anodic shift in the corrosion potential as it galvanically couples to the metal substrate. Standard electrochemical measurements revealed the steel coated with antiwetting nanostructured polythiophene film, which was immersed in chloride solution of different pH and temperature for up to 7 days, is very well protected from corrosion evidenced by protection efficiency of greater than 95%. Fabrication of the dual properties superhydrophobic anticorrosion nanostructured conducting polymer coating follows a two-step coating procedure that is very simple and can be used to coat any metallic surface.
A facile approach for enabling or inhibiting the adsorption of protein and adhesion of bacterial cells on a potential-induced reversibly wettable polythiophene film is described. The superhydrophobic polymeric surface was first prepared by a two-step process that combines the layering of polystyrene (PS) latex particles via a Langmuir–Blodgett (LB)-like technique followed by cyclic voltammetric (CV)–electrodeposition of polythiophene from a terthiophene ester monomer. The polythiophene conducting polymer coating enabled control of the wettability of the surface by simply changing its redox property via potential switching. The influence of morphology on this switching behavior is also described. The wettability in return controls the adsorption of protein and adhesion of bacterial cells. For instance, the undoped polythiophene film, which is superhydrophobic, inhibits the adhesion of fibrinogen proteins and Escherichia coli (E. coli) cells. On the other hand, the doped film, which is hydrophilic, leads to increased attachment of both protein and bacteria. Unlike most synthetic antiwetting surfaces, the as-prepared superhydrophobic coating is nonfluorinated. It maintains its superhydrophobic property at a wide range of pH (pH 1–13) and temperature (below −10 °C and between 4 and 80 °C). Moreover, the surface demonstrated self-cleaning properties at a sliding angle as low as 3° ± 1. The proposed methodology and material should find application in the preparation of smart or tunable biomaterial surfaces that can be either resistant or susceptible to proteins and bacterial cell adhesion by a simple potential switching.
Silicon continues to draw great interest as an anode
material for
lithium ion batteries due to its large specific capacity for lithium.
Macroporous silicon produced by electrochemical etching is one of
several anode materials of interest, but its energy density is oftentimes
limited due to its attachment to an unreactive silicon substrate.
Here, we present a novel “lift-off” method by which
a freestanding macroporous silicon film (MPSF) is electrochemically
detached from the underlying bulk silicon and combined with pyrolyzed
polyacrylonitrile (PAN), a conductive polymer that forms a conjugated-chain
chemical structure. We report the performance of these silicon thin
films with and without pyrolyzed PAN.
A folic acid sensor was prepared via an electropolymerized molecularly imprinted polymer (E-MIP) film of a bis-terthiophene dendron on a quartz crystal microbalance (QCM). The cyclic voltammetry (CV) electrodeposition of the imprinted polymer film was monitored by electrochemical QCM or E-QCM, enabling in situ monitoring and characterization of E-MIP film formation and the viscoelastic behavior of the film. A key component of the E-MIP process is the use of a bifunctional monomer design to precomplex with the template and function as a cross-linker. The complex was electropolymerized and cross-linked by CV to form a polythiophene matrix. Stable cavities were formed that specifically fit the size and shape of the folic acid template. The same substrate surface was used for folic acid sensing. The predicted geometry of the 1:2 folic acid/terthiophene complex was obtained through semiempirical AM1 quantum calculations. The analytical performance, expressed through the figures of merit, of the sensor in aqueous solutions of the analyte was investigated. A relatively good linearity, R(2) = 0.985, was obtained within the concentration range 0-100 μM folic acid. The detection limit was found to be equal to 15.4 μM (6.8 μg). The relative cross selectivity of the folic acid imprinted polymer against the three molecules follows this trend: pteroic acid (= 50%) > caffeine (= 41%) > theophylline (= 6%). The potential and limitations of the E-MIP method were also discussed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.