In modern mask manufacturing, a successful defect mitigation strategy has been become crucial to achieve defect free masks for high-end lithography. The basic steps of such a strategy include inspection, repair, and subsequent post-repair qualification of repair sites. For the latter task, actinic aerial image measurements have been proven to be the technique of choice to assess the printability of a repaired site. In the last three years, International SEMATECH in cooperation with Infineon/AMTC-Dresden and SELETE, funded a joint development project at Carl Zeiss to develop an AIMS tool operating at the 157nm wavelength. The three beta tools were shipped in 2003 to the three beta customer sites. In this paper are presented the first results obtained with these beta tools, including measurements on binary as well as alternating phase shift masks. The technical properties of the tool were discussed with regards to the capability of the tool for defect qualification on photomasks. Additionally, preliminary results of the evaluation of alternating phase shift masks will be discussed, including measurements performed on dense lines-and-spaces structures with various pitch sizes.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.