The aim of this article is to investigate patient satisfaction, survival rate of implants, and prosthetic complications or maintenance for rehabilitation with removable partial dentures associated with implants in mandibular Kennedy class I and II cases. A systematic literature review was conducted by three independent reviewers including articles published from January 1981 through September 2011. Medline and Cochrane Library electronic databases were used in addition to hand searching to assess clinical outcomes for mandibular implant-supported removable partial denture with distal extension. This review yielded 1751 records that were narrowed down to 5. The studies revealed implant survival rates ranging from 95% to 100% with one failure reported of 98 implants. The removable partial dentures associated with implant in mandibular free-end arches showed some complications and need of repair for relining, pitting of the healing abutment, replacement of resilient component of the attachment, damage in framework, screw loosening and damage in acrylic denture base. Patient satisfaction was evaluated through a five-point questionnaire, and results ranged between 4.12 and 5.0, considering 1 as the least favourable situation. The literature review showed increase in patient satisfaction and high survival rates of implants associated with mandibular removable partial dentures with distal extensions. However, some complications and need of prosthetic repair were reported. Although this treatment approach could represent a low-cost and beneficial rehabilitation for free-end mandibular ridges, the lack of controlled and randomised well-designed clinical trials suggests further studies with more representative samples to validate the outcomes of this treatment modality.
The aim of this review was to investigate the effectiveness of counselling and other self-management-based therapies on muscle and temporomandibular joint (TMJ) pain relief and increasing the functional abilities of patients with temporomandibular disorders (TMD). A systematic literature review was conducted by three independent reviewers and included articles published up to 2012. PubMed and Cochrane Library electronic databases were used in addition to hand-searching to assess clinical outcomes for counselling and self-management approaches for TMD treatment. The review yielded 581 records that were narrowed down to 7. All included studies were classified as blind-randomized controlled clinical trials. The selected articles analysed revealed that counselling was able to improve tenderness upon masticatory muscle palpation and maximum mouth opening with and without pain in patients with TMD, with similar results to those of interocclusal appliances approaches. Thus, counselling- and self-management-based therapies could be considered a conservative low-cost and beneficial treatment alternative for treating TMD to potentially improve psychological domains and remove harmful behaviours for the control of the signs and symptoms of TMD.
To investigate surface characteristics (roughness and contact angle), anti-biofilm formation, and mechanical properties (mini-flexural strength) of computeraided design and computer-aided manufacturing (CAD-CAM) polymethylmethacrylate (PMMA) polymer, and three-dimensional (3D) printed resin for denture base fabrication compared with conventional heat polymerized denture base resins. Materials and methods: A total of 60 discs and 40 rectangular specimens were fabricated from one CAD-CAM (AvaDent), one 3D printed (Cosmos Denture), and two conventional heat polymerized (Lucitone 199 and VipiWave) materials for denture base fabrication. Roughness was determined by Ra value; the contact angle was measured by the sessile drop method. The biofilm formation inhibition behavior was analyzed through Candida albicans adhesion, while mini-flexural strength test was done using a three-point bending test. The data were analyzed using descriptive and analytical statistics (α = 0.05).
Results:The CAD-CAM PMMA group showed the lowest C. albicans adhesion (log CFU/mL: 3.74 ± 0.57) and highest mini-flexural strength mean (114.96 ± 16.23 MPa). 3D printed specimens presented the highest surface roughness (Ra: 0.317 ± 0.151 μm) and lowest mini-flexural strength values (57.23 ± 9.07 MPa). However, there was no statistical difference between CAD-CAM PMMA and conventional groups for roughness, contact angle, and mini-flexural strength. Conclusions: CAD-CAM milled materials present surface and mechanical properties similar to conventional resins and show improved behavior in preventing C. albicans adhesion. Nevertheless, 3D printed resins present decreased mini-flexural strength.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.