Context:The newest variation of the i-gel supraglottic airway is a pediatric version.Aims:This study was designed to investigate the usefulness of the size 2 i-gel compared with the ProSeal laryngeal mask airway (PLMA) and classic laryngeal mask airway (cLMA) of the same size in anesthetized, paralyzed children.Settings and design:A prospective, randomized, single-blinded study was conducted in a tertiary care teaching hospital.Methods:Ninety ASA grade I–II patients undergoing lower abdominal, inguinal and orthopedic surgery were included in this prospective study. The patients were randomly assigned to the i-gel, PLMA and cLMA groups (30 patients in each group). Size 2 supraglottic airway was inserted according to the assigned group. We assessed ease of insertion, hemodynamic data, oropharyngeal sealing pressure and postoperative complications.Results:There were no differences in the demographic and hemodynamic data among the three groups. The airway leak pressure of the i-gel group (27.1±2.6 cmH2O) was significantly higher than that of the PLMA group (22.73±1.2 cmH2O) and the cLMA group (23.63±2.3 cmH2O). The success rates for first attempt of insertion were similar among the three devices. There were no differences in the incidence of postoperative airway trauma, sore throat or hoarse cry in the three groups.Conclusions:Hemodynamic parameters, ease of insertion and postoperative complications were comparable among the i-gel, PLMA and cLMA groups, but airway sealing pressure was significantly higher in the i-gel group.
Background:Although fluid bolus is considered as a conventional prophylactic measure to prevent spinal-induced hypotension; vasopressors are nevertheless required. Low dose spinal anesthetics could markedly reduce such episodes of hypotension, by minimizing sympathetic blockade.Aims:We chose to compare the relative efficacy of colloid preload versus coload under low dose spinal anesthesia, for elective cesarean delivery.Settings and Design:A prospective, randomized, double-blinded study.Materials and Methods:In total, 42 parturients were randomized to receive a preload (Group P) of hydroxyl ethyl starch (10 ml/kg) over 20 min before initiation of low dose spinal anesthesia (hyperbaric bupivacaine 5.5 mg with fentanyl 25 μg) or coload (Group C) of an identical fluid over 5 min, starting at the time of identification of cerebrospinal fluid. Our primary outcome included hemodynamic parameters and the incidence of hypotension. The neonatal outcome and side-effects were also monitored.Statistical Analysis:Mann-Whitney U test and Fisher's exact/Chi-square test, whichever appropriate. A P < 0.05 was considered to be significant.Results:The incidence of hypotension was lower in Group P (10%) when compared with Group C (25%), though insignificant statistically. The hemodynamic parameters were better in Group P, though intergroup statistical differences were not observed. The time to the first episode of hypotension was longer in the Group P (17 min) as compared with Group C (14 min). No notable side-effects or adverse neonatal outcome was noted.Conclusion:Colloid preload has a clinical advantage over the coload strategy, in reducing hypotensive episodes under low dose spinal anesthesia. Preload is better under large hemodynamic fluctuations while coload is preferable for emergency scenarios.
Ramosetron was found safe and more effective antiemetic than ondansetron in patients undergoing lap chole.
Background:Stylomastoid foramen is an important site for Nadbath facial nerve block. Exact localization of foramen holds the key to success, thus decreasing the complications. Wide racial variation exists in position of stylomastoid foramen in different population groups.Aim:The aim was to study the morphometry of stylomastoid foramen and its location with respect to nearby anatomical landmarks.Materials and Methods:A total of 100 dry skulls (60 male and 40 female) were studied to locate the position of center of stylomastoid foramen (CSMF) with respect to tip and anterior border of the mastoid process and jugular foramen (JF). Along with this angle between antero-posterior line passing through the tip of the mastoid process and line joining the tip with stylomastoid foramen was also measured.Result:In 83.51% sides of skulls, the most common position of foramen was found to be anterior to the line passing through anterior border of the mastoid process. The mean distance of center of foramen from the tip of the mastoid process was 15.26 ± 1.4 mm on right and 14.32 ± 1.8 on the left side (P < 0.001) and from JF was 12.28 ± 1.9 mm and 12.96 ± 2.1 mm on the right and left sides, respectively (P < 0.01). The position of CSMF was found at an angle of 66.57° ± 2.6° and 65.96° ± 1.8° on the right and left sides, respectively from the tip of the mastoid process.Conclusion:This study makes possible the identification of the exact position of stylomastoid foramen and its application in facial nerve block.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.