This is a call to action to nutrition support clinicians, societies, and organizations to proactively be involved in initiatives to educate clinicians and collaborate with EHR vendors to enhance the EHR systems to improve the safety and efficacy of providing nutrition therapy in hospitalized patients.
Failure to administer enteral nutrition, intravenous fluids, and/or parenteral nutrition solutions can have deleterious effects on patients who have been prescribed such therapies. However, it is not well understood why patients requiring nutrition support would be noncompliant or nonadherent to these often life-benefiting therapies. This article explores these issues in a large home nutrition support population.
delivery using a continuous synchronized beam delivery system. Continuous tracking of three LED markers, in conjunction with the timedependent radiographic position of the fiducial, was used to build correlation models to guide robot's compensation of the first-order target motion. Internal data from the system log-file was accessed to obtain marker model point positions, radiographic target positions, and the positional correlation error at the series of periodic time-points, analysis of which yielded a measure of the tracking accuracy. Results: Comparison of the 178 stereoscopic images defining the true target position with the 496 model points used for tracking yielded a mean positional correlation error of 1.8mm, 1.1mm, 1.8mm in x, y, z (system coordinates), with respective standard deviations of 1.4mm, 0.9mm, and 1.4mm. The mean radial 3D correlation error for the entirety of the treatment was 3.2mm with a standard deviation of 1.6mm; 90% of points had less than 5.5mm radial deviation, with outliers constituting model rebuilding. Conclusion: While phantom and animal experiments have produced preliminary data on the cardiac tracking under model conditions, the study presents the first in-patient determination of tracking accuracy for VT radio-ablation. Considering the mean magnitude and standard deviation of the 3D positional correlation error, a minimum 5mm margin should be used to account for accuracy of such surrogate-based tracking delivery.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.