A miniature electrostatic element has been designed to selectively apply a ninetydegree phase shift to the unscattered beam in the back focal plane of the objective lens, in order to realize Zernike-type, in-focus phase contrast in an electron microscope. The design involves a cylindrically shaped, biased-voltage electrode, which is surrounded by a concentric grounded electrode. Electrostatic calculations have been used to determine that the fringing fields in the region of the scattered electron beams will cause a negligible phase shift as long as the ratio of electrode length to the transverse feature-size is greater than 5:1. Unlike the planar, three-electrode einzel lens originally proposed by Boersch for the same purpose, this new design does not require insulating layers to separate the biased and grounded electrodes, and it can thus be produced by a very simple microfabrication process. Scanning electron microscope images confirm that mechanically robust devices with feature sizes of ~1 µm can be easily fabricated. Preliminary experimental images demonstrate that these devices do apply a 90-degree phase shift between the scattered and unscattered electrons, as expected. Powerful though modern electron microscopes have become, they still remain relatively poor instruments for imaging thin, unstained biological specimens. Such specimens are weakly-scattering "phase objects", which is to say that the intensity of the transmitted electron beam remains virtually equal to that of the incident electron beam. In this case, the effect of spatial variations in specimen structure is imprinted only on the phase of the transmitted wave. As was eloquently explained by Zernike, perfect images of such objects show no contrast [1]. As a result, weak phase objects must be intentionally viewed in an out-of-focus condition in order to partially convert the phase modulation into an intensity modulation. of 23The use of objective-lens defocus (and, at higher resolution, spherical aberration as well) is an imperfect way to produce phase contrast in images of biological macromolecules. The problem with that "simple" approach is that such phase shifts vary continuously over the spectrum of spatial frequencies. While the contrast transfer function produced as the result of an optimal trade-off between the phase distortion due to defocus and that due to spherical aberration can approximate the desired value of 1 over a relatively broad range of spatial frequencies [2], this band of high contrast is limited to rather high-resolution features of the image. Since it is necessary to have substantial contrast at low resolution in order to see biological macromolecules, however, it is often necessary to use a much larger amount of defocus. Unfortunately, when a high enough amount of defocus is used to generate contrast on the size scale of individual macromolecules, the phase shifts produced at high resolution can be many times the desired value of /2. As a result, the contrast transfer function then oscillates multiple times in ...
Volume x-ray gratings consisting of a multilayer coating deposited on a blazed substrate can diffract with very high efficiency even in high orders if diffraction conditions in-plane (grating) and out-of-plane (Bragg multilayer) are met simultaneously. This remarkable property however depends critically on the ability to create a structure with near atomic perfection. In this work we report on a method to produce these structures. We report measurements that show, for a 5000 l/mm grating diffracting in the 3 rd order, a diffraction efficiency of 37.6% at a wavelength of 13.6 nm, close to the theoretical maximum. This work now shows a direct route to achieving high diffraction efficiency in high order at wavelengths throughout the soft x-ray energy range.
A novel design is described for an aperture that blocks a half-plane of the electron diffraction pattern out to a desired scattering angle, and then – except for a narrow support beam – transmits all of the scattered electrons beyond that angle. Our proposed tulip-shaped design is thus a hybrid between the single-sideband (ssb) aperture, which blocks a full half-plane of the diffraction pattern, and the conventional (i.e. fully open) double-sideband (dsb) aperture. The benefits of this hybrid design include the fact that such an aperture allows one to obtain high-contrast images of weak-phase objects with the objective lens set to Scherzer defocus. We further demonstrate that such apertures can be fabricated from thin-foil materials by milling with a focused ion beam (FIB), and that such apertures are fully compatible with the requirements of imaging out to a resolution of at least 0.34 nm. As is known from earlier work with single-sideband apertures, however, the edge of such an aperture can introduce unwanted, electrostatic phase shifts due to charging. The principal requirement for using such an aperture in a routine data-collection mode is thus to discover appropriate materials, protocols for fabrication and processing, and conditions of use such that the hybrid aperture remains free of charging over long periods of time.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.