An 18-year-old male presented to the ophthalmology department with bilateral total subluxated cataract. On systemic examination, he was found to have grossly short stature, multiple severe bony deformities, hypogonadism and partial adontia. Detailed work-up revealed a biochemical and radiologic picture consistent with osteomalacia, which had resulted from malabsorption secondary to celiac disease, confirmed histopathologically. To the best of our knowledge, this is the first reported case of bilateral cataract as the presenting feature of celiac disease. Malabsorption leading to hypocalcemia along with chronic diarrhea itself may have contributed to the development of bilateral cataract.
Purpose:
The aim of this study was to describe a poly-vinyl chloride air condition (PVC AC) curtain shield placed at the intervening space between the chin rest and the illuminating and optical arm of the slit lamp microscope (distal barrier) instead of the present position at the oculars (proximal barrier) to guard against severe acute respiratory syndrome Coronavirus 2. This experimental study was done to validate and compare the protection offered by the conventional breath shields and the one described by us in a simulated environment.
Methods:
In this experimental study, 12 puffs of fine mist were sprayed over a period of 1 minute using “magenta-colored dye” and “cyan-colored dye” for analyzing proximal barrier and distal barrier respectively. To access the amount of contamination of the slit lamp, caused by sprayed “magenta” and “cyan” colored dye, we covered the entire slit lamp with appropriately sized white-colored cotton sheet. The stained sheets were individually photographed and then the images were first cropped, then color threshold adjusted and then converted to binary and finally fraction of surface area stained was calculated using the ImageJ software. (P
n
Surface Area
magenta fraction
(%) during analysis of “proximal barrier” and P
n
Surface Area
cyan fraction
(%) during the analysis of “distal barrier”, where P
n
refers to various parts of slit lamp.
Results:
The entire surface area of the cloth covering the slit lamp was 9912.45 cm
2
. The surface area of the cloth which was stained when using the “proximal barrier” was 567.50 cm
2
whereas when using the “distal barrier” was 222.93 cm
2
. When using proximal barrier, 97.71% of the staining was present on the slit lamp base, viewing arm, illumination arm and the pivot of the slit lamp. While using the distal breath shield no parts of the viewing arm, illumination arm, the pivot or the mechanical base with joystick were stained.
Conclusion:
The novel PVC AC curtain shield provides better barrier against the simulated contaminated stream of patient's breath directed towards the working parts of the slit lamp as compared to conventional slit lamp oculars mounted breath shields.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.