ML Flow and anti-PGL-I ELISA are serological tests that detect IgM antibodies against the phenolic glycolipid I (PGL-I), specific to Mycobacterium leprae. To evaluate the outcomes of ML Flow and ELISA (PGL-I) serological tests in leprosy-endemic areas in comparison to non-endemic ones, a total of 351 volunteers from Brazil and Chile were examined, including leprosy patients, healthy controls and others affected by other infectious or non-infectious diseases that are common differential diagnoses for leprosy. The ELISA cut-off point was established using the ROC Curve method (> 0.157). In endemic areas, 70% of leprosy patients present positive ML Flow results and 53.3% were ELISA-positive. In non-endemic areas, ML Flow was negative in all the subjects tested and ELISA was positive in 4 volunteers. ML Flow is faster and more easily performed and, therefore, a more adequate test for use in basic, primary-level health care centers. ELISA requires trained personnel, in addition to a more complex laboratory infrastructure.Key-words: Serologic tests. PGL-I antigen. Leprosy. ML Flow. ELISA. RESUMOO ML Flow e o ELISA PGL-I são testes sorológicos que detectam anticorpos IgM contra o glicolipídio fenólico I específico do Mycobacterium leprae. Para avaliar o comportamento destes testes em áreas endêmica e não endêmica para hanseníase foram estudados 351 voluntários no Brasil e no Chile, incluindo pacientes com hanseníase, controles sadios, portadores de outras doenças infecciosas, não infecciosas e dermatoses que fazem diagnóstico diferencial com hanseníase. O ponto de corte do ELISA foi estabelecido pelo método da Curva ROC (> 0,157). Em área endêmica, o ML Flow apresentou resultados positivos em 70% dos pacientes com hanseníase; o ELISA foi positivo em 53,3%. Em área não endêmica, o ML Flow foi negativo em todos os voluntários testados; o ELISA foi positivo em 4 voluntários. O ML Flow é um ensaio mais rápido, facilmente aplicável e, portanto, mais adequado para ser utilizado na Atenção Básica; o ELISA necessita, alem de uma infra-estrutura de laboratório adequada, pessoal treinado e especializado em sua execução.
A descriptive, exploratory study was conducted analyzing the association of covariables in the results of the ML Flow serological test and slit skin smear. A total of 60 leprosy cases diagnosed at the state Sanitary Dermatology Referral Center were investigated. Slit skin smear samples were collected from four sites and the results were expressed by the bacillary index. ML Flow was registered in both qualitative and semi-quantitative terms. Cohen's kappa coefficient was used to study the agreement with Landis and Koch's observer criteria for interpretation. For statistical analysis, the logistic regression model and Kruskal-Wallis test were used. ML Flow showed a strong association with slit skin smear results, since a gradual increase in BI was accompanied by a semi-quantitative rise in antibody levels measured by ML Flow, with 100% positivity in cases presenting a positive slit skin smear. Given its strong correlation to slit skin smear, the results of this study provide evidence that the ML Flow test could be a valuable auxiliary tool in the classification and treatment of leprosy patients. Key-words:Leprosy. Serological tests. Slit skin smear. ML Flow. RESUMORealizou-se estudo descritivo e exploratório relacionando as covariáveis aos resultados do teste sorológico ML Flow e baciloscopia. Foram estudados 60 casos novos de hanseníase diagnosticados no Centro de Referência em Dermatologia Sanitária. Para a baciloscopia, foi utilizada a coleta de esfregaço dérmico em quatro sítios, sendo o resultado expresso pelo índice bacilocópico. O ML Flow foi registrado de modo qualitativo e semi-quantitativo. Para o estudo da concordância, foi utilizado o índice de Kappa e, para sua interpretação, os critérios de Landis e Koch. Para análise estatística foram realizados a regressão logística e o teste de Kruskal-Wallis. O ML Flow mostrou forte associação com a baciloscopia, observou-se que o aumento gradativo do índice baciloscópico foi acompanhado pelo aumento semi-quantitativo dos níveis de anticorpos medidos pelo ML Flow, tendo sido positivo em 100% dos casos com baciloscopia positiva. Os resultados deste estudo evidenciaram que o ML Flow, por estar fortemente correlacionado à bacilocopia, poderá tornar-se um valioso instrumento auxiliar na classificação e alocação dos pacientes para fins de tratamento.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.