For a sensorless predictive-peak-current-controlled boost converter, the output voltage steady-state error cannot be eliminated by voltage loop PI controller. The basic cause for this is investigated through analysis and theoretical approaches. To eliminate the voltage steady-state error and achieve high-accuracy current estimation, a comprehensive compensation strategy is proposed. First, a compensation algorithm for output voltage sampling is introduced. It can not only effectively eliminate the output voltage steady-state error but also guarantee current observer convergence. The compensation schemes for component parasitic parameter effects and switching delay are also investigated. With this comprehensive compensation strategy, both the system transient response and current estimation accuracy are greatly improved. Finally, the effectiveness of the proposed algorithm is verified by experimental results.
For a sensorless predictive current controlled boost dc-dc converter, its small-signal model that contains a number of parasitic parameters, is derived in this paper. This model indicates that the type of system becomes type 0 even with the correction of voltage loop proportional-integral controller, leading to the existence of output voltage steady-state error. Then a self-correction differential current observer (SDCO) is proposed to eliminate this steady-state error and gain high transient response speed. The self-correction part of the SDCO makes the system become type 1 to achieve no steady-state error for output voltage, whereas the differential part can guarantee that the intermediate calculation results do not overflow. By carrying out a series of simulation verifications, further investigation proves that the proposed algorithm has good robustness. Finally, the effectiveness of the proposed algorithm is verified by experimental results.
Abstract-In a sensorless predictive current controlled boost converter, parameterizing the inductor plays an important role in controller performance. In this paper, a solution for inductor parameters online identification is investigated. A small signal injection strategy is proposed to create a transient state, and convergence problem of inductance identification in steady state can be avoided. Then a charge balance current observer (CBCO), derived from capacitor current charging balance concept, is adopted to estimate the inductor current for inductance identification. Since inductance is not used in CBCO, current estimation is not affected by inductance identification error. Because of rank-deficient problem, instead of identifying inductor parasitic resistance solely, the inductor equivalent parasitic resistance is derived. By applying it into the conventional current observer for current control loop, the accuracy of current estimation can still be guaranteed since more parasitic effects are included. To improve the accuracy of inductance identification, a load identification method is investigated. Furthermore, the effect of the equivalent series resistance (ESR) of output capacitor on the proposed algorithm is analyzed. Finally, its effectiveness is verified by experimental results.Index Terms-Sensorless, boost converter, inductor parameters, online identification, small signal injection.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.