The in vitro effect of 6-day storage of platelets prepared from 6 pooled buffy coat (BC) units and stored in a platelet storage medium containing approximately 40 percent CPD-plasma and 60 percent platelet additive solution (PAS) was evaluated. PAS is composed of sodium and potassium chloride, citrate, phosphate, and mannitol. The total count of platelets per pooled unit included in the in vitro studies (n = 25) was 376 +/- 59 x 10(9) (mean +/- SD). The present study included three steps. 1. Evaluation of platelet storage in one (n = 7) and two (n = 6) 1000-mL polyolefin containers using PAS. During storage in one container, significantly lower values were found for pH, pO2, glucose, ATP, and the ratio of ATP to AMP+ADP+ATP. The values for mean platelet volume, pCO2, lactate, and extracellular adenylate kinase activity were significantly higher. These results indicate that storage in only one polyolefin container is not appropriate for maintaining satisfactory platelet quality. During storage in two polyolefin containers, a remarkably decreased lactate production (0.07 +/- 0.02 mmol/day/10(11) platelets) was noted. 2. PAS was substituted for saline during 6-day storage in two 1000-mL polyolefin containers (n = 12). The composition of the platelet preparations was the same in all other respects. Similar in vitro results were noted with PAS and saline, which indicated that PAS has no specific effect on the storage of platelets different from that of saline.(ABSTRACT TRUNCATED AT 250 WORDS)
The effect of storage of platelets in a new polyvinyl chloride (PVC) plastic material with a butyryl-n-trihexyl citrate (BTHC) plasticizer (PL 2209) was evaluated. The PL 1240 container, i.e. PVC plastic with a different plasticizer, tri-(ethylhexyl)-tri-mellitate, was used as a reference. Measurements of pH, pO2, pCO2, glucose, lactate, adenosine triphosphate, total adenine nucleotide content, lactate dehydrogenase and platelet factor 4 (PF4) were made during 5 days of storage. Similar results were noted comparing PL 2209 and PL 1240. Differences in pO2 and pCO2 indicate greater gas permeability in PL 2209 than in PL 1240. Significantly higher PF4 levels were found in PL 2209, but the difference could not be attributed to the PL 2209 container itself. Paired autologous reinfusion studies (111Indium) of 6 normal donors gave mean recovery values after 5-day storage of 41.1 +/- 7.4% (PL 2209) and 45.5 +/- 7.7% (PL 1240), t1/2 66 +/- 13 and 75 +/- 5 h, survival time (linear model) 6.3 +/- 1.0 and 6.8 +/- 0.7 and survival time (multiple-hit model) 6.0 +/- 0.7 and 6.5 +/- 0.4 days, respectively. Only the difference in survival time (multiple-hit) was significantly higher in PL 1240. The corrected count increments at 12-24 h following transfusion were 13,300 +/- 10,800 (PL 2209) and 13,600 +/- 11,600 (PL 1240) with no statistically significant difference found. These results indicate PL 2209 as an equivalent alternative to PL 1240 for the 5-day storage of platelets.
Alloimmunized, thrombocytopenic patients, refractory to random-donor platelet transfusion, often respond to HLA-identical single-donor platelets. HLA-compatible platelets are expensive, take time to prepare, and donors are sometimes not to be found. We have used random-donor platelets and 'peeled' the HLA-antigen off the platelets, using a modified laboratory method (incubation of platelets with citric acid solution at 0 degrees C). Platelet recovery in two healthy subjects was 72.0% for acid-treated platelets, and 73.5% for untreated control platelets, using 111In-labelled autologous platelets. Survival time (multiple hit) was 6.25 and 7.95 d, respectively. Random-donor platelets that were strongly positive in the crossmatch with serum from a patient became negative after treatment with the acid solution. Furthermore, transfusion of these platelets gave a post-transfusion, platelet-count increment comparable with transfusion of HLA-compatible single-donor platelets.
We have modified previously described solid-phase tests for erythrocyte antibody screening to develop a method, suitable for antiglobulin- and enzyme-enhanced techniques (SPH-IAT and SPH-ENZ). In this study we compared the SPH tests with an autoanalyzer (AA) technique. The results were more specific with the SPH tests than with the AA. Of 4,234 unselected samples from pregnant women, screen-positive samples were reduced from 96 (2.27%) by the AA, to 56 (1.32%) by the SPH tests. This difference was due to the reduced number of false-positive reactions with the SPH tests, 0.47% compared to 1.44% with the AA. Antibodies detected by the AA and the SPH-IAT and -ENZ were: 9 Rh prophylaxis, 2 anti-c, 1 anti-K and anti-M, and 1 anti-Jka. Antibodies detected only by the SPH tests were 1 anti-K, 1 anti-Le(a) (SPH-IAT and -ENZ), 1 anti-M (SPH-IAT) and 4 anti-Jka (SPH-ENZ). One anti-C, 2 anti-D, 3 Rh prophylaxis and 1 anti-E were detected by the AA and the SPH-ENZ but failed to react by the SPH-IAT. One anti-Le(a) and 8 Rh prophylaxis antibodies were detected by AA only. All clinically important antibodies were detected by the SPH tests. We conclude that the SPH-IAT and SPH-ENZ are screening methods with high specificity that are readily adaptable to larger series of samples from pregnant women and suitable for automated handling throughout the screening and identification process.
The PEG-IAT microplate method gave reliable results that were suitable for routine phenotyping, thus making available a stock of phenotyped blood at reasonable cost, ready for delivery when required.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.