In general, the sensitivity of ferrimagnetic Faraday effect magnetic field sensors is a function of both the crystal geometry and composition. The geometrical dependence of the sensitivity in nonellipsoidal crystals, such as cylinders, is complicated by their spatially nonuniform demagnetizing factors. We compare sensitivity data obtained from a variety of cylindrical iron garnet samples with models which predict the effective demagnetizing factor Neff as a function of the length-to-diameter ratio. With respect to composition, we present experimental results of sensitivity vs diamagnetic substitution (x) in the iron garnet series Y3Fe5−xGaxO12. As expected, the sensitivity rises sharply as x approaches the compositional compensation point.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.