This paper describes observations made on studies carried in laboratory trials by using electro-coagulation process using iron electrodes. The purpose of this study is to present the iron electrode-based EC procedure, its superiority over other technologies used for removing arsenic from ground water and surface water. In order to reduce arsenic (As), it was also necessary to understand the basics of the electrochemical process (EC) and the significance of its operating conditions, such as anode materials, applied voltage, pH and anode distance. At different concentration of Arsenic (500ppb, 200ppb & 100 ppb) it was observed that with the higher concentration i.e. 500 ppb there is faster decrease in arsenic concentration at 6.5 pH. While, when using different current density 0.5 A & 1.0 A at (12V) almost same results were obtained i.e. arsenic removal took place in same time duration at a pH range of 3.5 to 6.5. It was also observed that arsenic concentration decreases with electrode spacing, size of electrodes and contact time of treatment.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.