Background: Animal spinal cord injury (SCI) models have provided a better perception of the mechanisms related to traumatic SCI and evaluation of the effectiveness of experimental therapeutic interventions. Objectives: The aim of this study is to develop a cost-effective modified Allen's device to induce contusive spinal cord injury. Methods: Adult male Wistar rats were subjected to contusive spinal cord injury using a customized weight drop model through 10-g weights delivered from a 25-mm height onto an exposed spinal cord. Locomotor and sensory function during 28 days were assessed. Moreover, histopathological changes were assessed at one week and 28 days post SCI. Results: All the SCI rats showed hind limb paralysis up to 48 h post SCI and neuropathic pain after injury. Histological changes similar to the previous reports for contusion model were observed. Conclusions: According to our findings, little variability was observed in the BBB score of individual rats at 28 days after injury. Our customized device to induce spinal cord injury is a simple and inexpensive alternative method to the highly sophisticated contusion device commonly used to induce SCI.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.