Haemostatic and aseptic effects and intricate cut geometry are beneficial aspects of non-contact laser osteotomy. Collateral thermal damage, however, has severely limited the use of conventional lasers. The purpose of this study was to test the side effects on bone after cutting it with short CO2 laser pulses and simultaneous application of a fine air-water spray. The 10.6 microm CO2 laser emitted 80 micros pulses of 46 mJ energy, f=100 Hz, focused to a spot diameter of 130 ìm. Scan rate amounted to 40 mm/s. To approximate live conditions 10 samples of cortical bone and 10 rib segments were prepared immediately after sacrificing of pigs. A reference cut with a bandsaw and three laser cuts with an increasing number of beam passes (4, 16, 64) were performed on each sample. Half of the samples were decalcified in EDTA. The others were embedded in plastic to cut non-decalcified sections. The laser incisions were not accompanied by carbonisation. The incisions with slightly convergent walls were 150 ìm wide. The depths of the cavities increased with the number of the beam passes from approximately 0.5 mm (4 passes) to 3 mm (64 passes). At the border of the incisions two narrow zones of damage were noted: an amorphous intensively stained zone of 1-3 microm width and a wider, also sharply demarcated but faintly stained zone of 7-10 microm. A broader zone of about 50 microm was characterised by empty lacunae and osteocyte damage. These effects were not predictable; intact osteocytes were also observed near to the cut surface. Polarised light microscopy showed no alterations in the inorganic structure of the bone at the cut borders. The histological results indicated only minimal damage to bone ablated at the specified parameters. The described laser procedure might have advantages over mechanical instruments.
An effective CO(2) laser osteotomy without aggravating thermal side effects and healing delay is possible using the described irradiation technique. It allows an arbitrary cut geometry and may result in new advantageous bone surgery procedures.
Systematic investigations on ablation of compact bone tissue with different CO 2 laser systems are presented. Main attention is paid to the influence of the laser wavelength and pulse duration on the efficiency of the ablation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.