Potentiometric sensors have a great influence on the determination of most various compounds in their matrices. Therefore, efficient and new sensors were introduced to measure sodium Deoxycholate (NaDC) as a bile acid salt. These sensors are based on NaDC imprinted polymer (MIP) as sensory element. The MIP beads were synthesized using thermal polymerization pathway, in which acrylamide (AAm), ethylene glycol dimethacrylate (EGDMA), NaDC, and benzoyl peroxide (BPO) were used as the functional monomer, cross-linker, template, and initiator, respectively. The proposed sensors were fabricated using a coated screen-printed platform and the sensing membrane was modified by single-walled carbon nanotubes (SWCNTs) as an ion-to-electron transducer. The sensors exhibited high sensitivity that reached 4.7 × 10−5 M of near-Nernestian slope (−60.1 ± 0.9 mV/decade, r2 = 0.999 (n= 5)). In addition, the sensors revealed high selectivity, long lifetime, high potential stability, and conductivity that ensure reproducible and accurate results over a long time. MIP characterization was performed using Fourier Transform-Infrared (FT-IR) and a scanning electron microscope (SEM). Regarding the interaction of NaDC with serum albumin (SA), albumin is determined in human serum samples as human serum albumin (HSA), which was collected from different volunteers of different ages and gender.
A novel single-piece all-solid-state ion-selective electrode (SC/ISE) based on carbon-screen printed is introduced. Polyaniline (PANI) is dissolved in a membrane cocktail that contains the same components used for making a conventional ion-selective polyvinyl chloride (PVC) matrix membrane. The membrane, having the PANI, is directly drop-casted on a carbon substrate (screen-printed-carbon electrode). PANI was added to act as an intermediary between the substrate and the membrane for the charge transfer process. Under non-equilibrium sensing mechanism, the sensors revealed high sensitivity towards 2,4-dichlorophenol (DCP) over the linearity range 0.47 to 13 µM and a detection limit 0.13 µm. The selectivity was measured by the modified separate solution method (MSSM) and showed good selectivity towards 2,4-DCP over the most commonly studied ions. All measurements were done in 30 mm Tris buffer solution at a pH 5.0. Using constant-current chronopotentiometry, the potential drift for the proposed electrodes was checked. Improvement in the potential stability of the SPE was observed after the addition of PANI in the sensing membrane as compared to the corresponding coated-wire electrode (membrane without PANI). The applicability of the sensor has been checked by measuring 2,4-DCP in different water samples and the results were compared with the standard HPLC method.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.