X-ray hybrid CMOS detectors (HCDs) are a promising candidate for future x-ray missions requiring high throughput and fine angular resolution along with large field-of-view, such as the high-definition x-ray imager (HDXI) instrument on the Lynx x-ray surveyor mission concept. These devices offer fast readout capability, low power consumption, and radiation hardness while maintaining high detection efficiency from 0.2 to 10 keV. In addition, x-ray hybrid CMOS sensors may be fabricated with small pixel sizes to accommodate high-resolution optics and have shown great improvements in recent years in noise and spectral resolution performance. In particular, 12.5-μm pitch prototype devices that include in-pixel correlated double sampling capability and crosstalk eliminating capacitive transimpedance amplifiers, have been fabricated and tested. These detectors have achieved read noise as low as 5.4 e − , and we measure the best energy resolution to be 148 eV (2.5%) at 5.9 keV and 78 eV (14.9%) at 0.53 keV. We will describe the characterization of these prototype small-pixel x-ray HCDs, and we will discuss their applicability to the HDXI instrument on Lynx. © The Authors. Published by SPIE under a Creative Commons Attribution 4.0 Unported License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI.
The Penn State X-ray detector lab, in collaboration with Teledyne Imaging Sensors (TIS), have progressed their efforts to improve soft X-ray Hybrid CMOS detector (HCD) technology on multiple fronts. Having newly acquired a Teledyne cryogenic SIDECAR TM ASIC for use with HxRG devices, measurements were performed with an H2RG HCD and the cooled SIDECAR TM . We report new energy resolution and read noise measurements, which show a significant improvement over room temperature SIDECAR TM operation. Further, in order to meet the demands of future high-throughput and high spatial resolution X-ray observatories, detectors with fast readout and small pixel sizes are being developed. We report on characteristics of new X-ray HCDs with 12.5 micron pitch that include in-pixel CDS circuitry and crosstalk-eliminating CTIA amplifiers. In addition, PSU and TIS are developing a new large-scale array Speedster-EXD device. The original 64 × 64 pixel Speedster-EXD prototype used comparators in each pixel to enable event driven readout with order of magnitude higher effective readout rates, which will now be implemented in a 550 × 550 pixel device. Finally, the detector lab is involved in a sounding rocket mission that is slated to fly in 2018 with an off-plane reflection grating array and an H2RG X-ray HCD. We report on the planned detector configuration for this mission, which will increase the NASA technology readiness level of X-ray HCDs to TRL 9.
X-ray Hybrid CMOS Detectors (HCDs) have advantages over X-ray CCDs due to their higher readout rate abilities, flexible readout, inherent radiation hardness, and low power, which make them more suitable for the next generation large-area X-ray telescope missions. The Penn State high energy astronomy laboratory has been working on the development and characterization of HCDs in collaboration with Teledyne Imaging Sensors (TIS). A custom-made H2RG detector with 36 µm pixel pitch and 18 µm ROIC shows an improved performance over standard H1RG detectors, primarily due to a reduced level of inter-pixel capacitance crosstalk (IPC). However, the energy resolution and the noise of the detector and readout system are still limited when utilizing a SIDECAR at non-cryogenic temperatures. We characterized an H2RG detector with a Cryo-SIDECAR readout and controller, and we find an improved energy resolution of ∼2.7 % at 5.9 keV and read noise of ∼6.5 e-. Detections of the ∼0.525 keV Oxygen Kα and ∼0.277 keV Carbon Kα lines with this detector display an improved sensitivity level at lower energies. This detector was successfully flown on NASA's first water recovery sounding rocket flight on April 4 th , 2018. We have also been developing several new HCDs with potential applications for future X-ray astronomy missions. We are characterizing the performance of small-pixel HCDs (12.5 µm pitch), which are important for the development of a next-generation high-resolution imager with HCDs. The latest results on these small pixel detectors has shown them to have the best read noise and energy resolution to-date for any X-ray HCD, with a measured 5.5 e-read noise for a detector with in-pixel correlated double sampling. Event recognition in HCDs is another exciting prospect. We characterized a 64 × 64 pixel prototype Speedster-EXD detector that uses comparators in each pixel to read out only those pixels having detectable signal, thereby providing an order of magnitude improvement in the effective readout rate. Currently, we are working on the development of a large area Speedster-EXD with a 550 × 550 pixel array. HCDs can also be utilized as a large FOV instrument to study the prompt and afterglow emissions of GRBs and detect black hole transients. In this context, we are characterizing a Lobster-HCD system for future CubeSat experiments. This paper briefly presents these new developments and experimental results.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.