Breath tests used to evaluate carbohydrates malabsorption require baseline H2 and CH4 levels as low as possible. Test cancellation is recommended when exceeding certain cut-offs (H2 ≥ 20 ppm and CH4 ≥ 10 ppm). Although following preparation protocols, many patients have baseline levels above those cut-offs. We investigated if light walking can reduce baseline H2 and CH4 levels. We retrospectively analyzed baseline H2 and CH4 levels from 1552 breath tests. Baseline levels (B1), especially in H2, were lower when obtained at later hours of the day. In those with baseline levels above cut-off, re-sampling (B2) after light walking for one hour, decreased H2 levels 8 ppm (Q1–Q3: 1–18 ppm), and 2 ppm (Q1–Q3: 0–3 ppm) for CH4. Consequently, 40% of tests with elevated B1 levels, presented B2 levels below mentioned cut-offs. Ten percent of tests considered negative when using B1 for calculations, turned positive when using B2 instead. All positive tests when using B1 values, remained elevated when using B2. Re-sampling after light walking for one hour could allow test performance in those with previous elevated baseline levels, avoiding diagnosis delays. Using the second sample for delta calculations identifies positive patients for malabsorption that would have been considered negative.
Objectives Remote self-collected capillary blood samples have been proposed as alternative to venous blood samples as an aid in telemedicine. The aim of this work is to compare the preanalytical and analytical performance of these two types of samples and to study the stability of common measurands in capillary blood. Methods Capillary and venous blood samples were collected in parallel from 296 patients in serum tubes to analyze 22 common biochemistry magnitudes after centrifugation and in EDTA tubes to analyze 15 hematologic magnitudes. Quality of the preanalytical process was assessed applying the model of quality indicator. 24 h stability at room temperature was studied by obtaining paired capillary samples. A questionnaire of assessment was conducted. Results Mean hemolysis index was higher in capillary samples compared to venous blood samples (p<0.001). Regression analysis and difference analysis showed no bias for all studied biochemistry parameters and hematologic parameters, except mean corpuscular volume (MCV), between capillary and venous blood samples. Regarding sample stability, percentage deviation was higher than the corresponding minimum analytical performance specification for ferritin, vitamin D, hematocrit, MCV, mean corpuscular hemoglobin concentration, platelets distribution wide, mean platelet volume and basophils. Finger pricking was perceived as less painful (p<0.05) than venipuncture in participants who undergo more than one blood test per year. Conclusions Capillary blood can be used as an alternative to venous blood for the studied parameters in automated common clinical analyzers. Cautious should be taken if samples are not analyzed within 24 h from the collection.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.