Background: Total body water (TBW) estimations have been used to estimate body composition, particularly fat-free mass, to aid in nutritional interventions, and to monitor hydration status. In the past, bioimpedance spectroscopy (BIS) devices have been used to estimate TBW. Previous investigations have examined the validity of the XiTRON 4000B (XiTRON Technologies) BIS device for estimating TBW. Recently, a new BIS device (Imp™ SFB7) has become available, claiming greater precision when estimating TBW. The Imp™ SFB7 (SFB7) is based on similar BIS principles, while offering increased portability and a greater range of frequencies when compared to older devices, such as the XiTRON 4000B (4000B). The purpose of this study was to examine the validity of the SFB7 for estimating total body water in healthy college-age men and women compared to the 4000B and deuterium oxide (D 2 O).
The purpose of the present study was to determine the validity of various laboratory methods for estimating percent body fat (%fat) in NCAA Division I college female athletes (n = 29; 20 +/- 1 year). Body composition was assessed via hydrostatic weighing (HW), air displacement plethysmography (ADP), and dual-energy X-ray absorptiometry (DXA), and estimates of %fat derived using 4-compartment (C), 3C, and 2C models were compared to a criterion 5C model that included bone mineral content, body volume (BV), total body water, and soft tissue mineral. The Wang-4C and the Siri-3C models produced nearly identical values compared to the 5C model (r > 0.99, total error (TE) < 0.40%fat). For the remaining laboratory methods, constant error values (CE) ranged from -0.04%fat (HW-Siri) to -3.71%fat (DXA); r values ranged from 0.89 (ADP-Siri, ADP-Brozek) to 0.93 (DXA); standard error of estimate values ranged from 1.78%fat (DXA) to 2.19%fat (ADP-Siri, ADP-Brozek); and TE values ranged from 2.22%fat (HW-Brozek) to 4.90%fat (DXA). The limits of agreement for DXA (-10.10 to 2.68%fat) were the largest with a significant trend of -0.43 (P < 0.05). With the exception of DXA, all of the equations resulted in acceptable TE values (<3.08%fat). However, the results for individual estimates of %fat using the Brozek equation indicated that the 2C models that derived BV from ADP and HW overestimated (5.38, 3.65%) and underestimated (5.19, 4.88%) %fat, respectively. The acceptable TE values for both HW and ADP suggest that these methods are valid for estimating %fat in college female athletes; however, the Wang-4C and Siri-3C models should be used to identify individual estimates of %fat in this population.
Background: Exercise and high-protein/reduced-carbohydrate and -fat diets have each been shown separately, or in combination with an energy-restricted diet to improve body composition and health in sedentary, overweight (BMI > 25) adults. The current study, instead, examined the physiological response to 10 weeks of combined aerobic and resistance exercise (EX) versus exercise + minimal nutrition intervention designed to alter the macronutrient profile, in the absence of energy restriction, using a commercially available high-protein/low-carbohydrate and low-fat, nutrient-dense food supplement (EXFS); versus control (CON).
Energy drink use has grown despite limited research to support efficacy or safety and amid concerns when combined with exercise. The purpose of this study was to assess the effects of 10 weeks of once-daily energy drink consumption or energy drink consumption with exercise on measures of body composition, cardiorespiratory fitness, strength, mood, and safety in previously sedentary males. Thirty-eight males were randomly assigned to energy drink + exercise (EX-A), energy drink (NEX-A), placebo + exercise (EX-B), or placebo (NEX-B). All participants consumed 1 drink per day for 10 weeks; EX-A and EX-B participated in 10 weeks of resistance and endurance exercise. Testing was performed before (PRE) and after (POST) the 10-week intervention. No significant (p > 0.05) changes were observed for body composition, fitness, or strength in NEX-A; however, significantly greater decreases in fat mass and percentage body fat and increases in VO2peak were observed in EX-A versus EX-B. Ventilatory threshold (VT), minute ventilation, VO2 at VT, and power output at VT improved significantly PRE to POST in EX-A but not in EX-B or nonexercising groups. Clinical markers for hepatic, renal, cardiovascular, and immune function, as determined by PRE and POST blood work revealed no adverse effects in response to the energy drink. Mood was not affected by energy drink use. Absent energy restriction or other dietary controls, chronic ingestion of a once-daily low-calorie energy drink appears ineffective at improving body composition, cardiorespiratory fitness, or strength in sedentary males. However, when combined with exercise, preworkout energy drink consumption may significantly improve some physiological adaptations to combined aerobic and resistance training.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.