Sagittal pelvic kinematics along with spino-pelvic angular parameters have recently been studied by numerous investigators for their effect on total hip replacement (THR) clinical outcomes, but many issue of spine-hip relations (SHR) are currently unexplored. Therefore, our review aims at clarifying the following questions: is there any evidence of a relationship between articular impingement/dislocation risk in primary THR and (1) certain sagittal pelvic kinematics patterns, (2) pelvic incidence, and (3) types of SHRs? A systematic review of the existing literature utilising PubMed and Google search engines was performed in January 2017. Only clinical or computational studies published in peer-reviewed journals over the last five years in either English or French were reviewed. We identified 769 reports, of which 12 met our eligibility criteria. A review of literature shows that sagittal pelvic kinematics, but not the pelvic incidence, influences the risk of prosthetic impingement/dislocation. We found no study having assessed the relationship between this risk and the types of SHRs. Sagittal pelvic kinematics is highly variable among individuals and certain kinematic patterns substantially influences the risk of prosthetic impingement/dislocation. Recommendations for cup positioning are therefore switching from a systematic to a patient-specific approach, with the standing cup orientation Lewinneck safe zone progressively giving way to a new parameter of interest: the functional orientation of the cup. Based on a recently published classification for SHRs, We propose a new concept of "kinematically aligned THR" for the purposes of THR planning. Further studies are needed to investigate the relevance of such a classification towards the assumptions and hypothesis we have made. Level of evidence,- Level IV, systematic review of level III and IV studies.
We treated 50 consecutive patients with infected total hip arthroplasties according to a standard protocol. Previous surgery to eradicate the infection had been attempted in 13 patients and discharging sinuses were present in 20. Aspiration arthrography was routinely carried out before our interventions. The first stage was a meticulous removal of all foreign and potentially infected material. Samples were taken for culture and a thorough lavage carried out. Antibiotic-loaded beads were placed in the femoral shaft and an antibiotic-loaded cement ball in the acetabulum. At the second stage an uncemented arthroplasty was introduced. Bone allograft was used in 18 patients. The interval between procedures was usually three weeks, but this was extended if the wound was slow to heal or there was extensive bony destruction. Appropriate antibiotics were given for three months. At a mean follow-up of 5.8 years the rate of reinfection was 8% (4 patients). Two of these patients have had another, successful, two-stage revision. At this medium-term review, a satisfactory clinical and radiological outcome was obtained in all except two patients.
Widespread concern exists about adverse tissue reactions after metal-on-metal (MoM) total hip replacement (THR). Concerns have also been expressed with wear and corrosion of taper junctions in THR. We report the effect of surface finish and contact area associated with a single combination of materials of modular tapers. In an in vitro test, we investigated the head/neck (CoCrMo/ Ti) interface of modular THRs using commercially available heads. Wear and corrosion of taper surfaces was compared following a 10 million loading cycle. Surface parameters and profiles were measured before and after testing. Electrochemical static and dynamic corrosion tests were performed under loaded and non-loaded conditions. After the load test, the surface roughness parameters on the head taper were significantly increased where the head/neck contact area was reduced. Similarly, the surface roughness parameters on the head taper were significantly increased where rough neck tapers were used. Corrosion testing showed breaching of the passive film on the rough but not the smooth neck tapers. Thus, surface area and surface finish are important factors in wear and corrosion at modular interfaces. ß
We carried out a cross-sectional study with analysis of the demographic, clinical and laboratory characteristics of patients with metal-on-metal hip resurfacing, ceramic-on-ceramic and metal-on-polyethylene hip replacements. Our aim was to evaluate the relationship between metal-on-metal replacements, the levels of cobalt and chromium ions in whole blood and the absolute numbers of circulating lymphocytes. We recruited 164 patients (101 men and 63 women) with hip replacements, 106 with metal-on-metal hips and 58 with non-metal-on-metal hips, aged < 65 years, with a pre-operative diagnosis of osteoarthritis and no pre-existing immunological disorders. Laboratory-defined T-cell lymphopenia was present in 13 patients (15%) (CD8(+) lymphopenia) and 11 patients (13%) (CD3(+) lymphopenia) with unilateral metal-on-metal hips. There were significant differences in the absolute CD8(+) lymphocyte subset counts for the metal-on-metal groups compared with each control group (p-values ranging between 0.024 and 0.046). Statistical modelling with analysis of covariance using age, gender, type of hip replacement, smoking and circulating metal ion levels, showed that circulating levels of metal ions, especially cobalt, explained the variation in absolute lymphocyte counts for almost all lymphocyte subsets.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.