In contact resonance force microscopy and related dynamic atomic force microscopy methods, an accurate description of the real-time cantilever dynamics is essential to the mapping of local material properties, such as viscoelasticity, piezo response, and chemical composition. Stiffness and damping variations of the tip-sample contact result in variations in the cantilever's resonance frequency and quality factor as it scans a sample of interest. When measuring characteristics of the resonance, generally, there is a tradeoff between full spectral coverage, best obtained by sweeping the amplitude versus frequency response in the time or frequency domain, and high-speed information, obtained by observing the cantilever response at one or two discrete frequencies, that may be required to track a resonance frequency that changes spatially. Here, we introduce a new option for performing contact resonance force microscopy with a low-cost multifrequency lock-in amplifier system with up to eight simultaneous independent excitation and detection frequencies. We demonstrate how the multifrequency approach can measure contact resonance frequency, quality factor, amplitude, and phase during imaging, with high precision and error estimation, without the need for frequency-tracking feedback. We show, using a wood composite sample, that this multifrequency approach can determine resonance frequency and quality factor, and associated uncertainty. This ability to estimate uncertainty of resonance parameters is not possible with 1 and 2 frequency methods. We further utilize the multifrequency lock-in to develop a novel means of increasing the stiffness range for highly sensitive nanomechanical sensing by dividing the eight lock-in frequencies to monitor two or four simultaneous eigenmodes, each of which is optimized for sensitivity in a particular stiffness regime. Overall, we show how multifrequency lock-in amplifiers with observation frequency chosen to coincide with an expected eigenmode's contact resonance can benefit the characterization of strongly heterogeneous samples, while maintaining fast measurement speed.
An accurate MATLAB-based CAD algorithm for quickly designing microstrip-based stepped-impedance resonator (SIR) low-pass filter is reported. The algorithm uses a circuit-theory approach to implement speedy computations, compared to the time-consuming computations involved in using electromagnetic theory. The accuracy of the proposed algorithm is verified for two widely-different practical examples in the 0-4GHz frequency range, against results obtained using Ansoft/Ansys circuit simulation tool, and against results obtained using the 3D electromagnetic simulator HFSS. The agreement among the three sets of data is seen to be excellent for most cases, and is found to be practically acceptable in the worst-case.
Relative intensity noise (RIN) inherent in fiber lasers poses a serious obstacle to their use in pump–probe spectroscopy and imaging. RIN can be removed through an analog balanced detector, or, as we have previously shown, software adaptive noise cancellation (ANC) on digitized signals. One major drawback to software ANC is the added time required for digitizing and post-processing. In this article, we describe a design for ANC on a field-programmable gate array (FPGA), making use of high-level synthesis tools and fixed-point arithmetic to achieve real-time laser RIN suppression at 25 MHz sample rates. Unlike the software-ANC approach, the FPGA-ANC device can serve as a dedicated drop-in denoiser, placed between the detectors and a commercial lock-in amplifier. We demonstrate its application to transient absorption spectroscopy and microscopy, lowering the noise floor to ∼17 dB above the shot noise limit. Furthermore, we demonstrate a dramatic improvement in data acquisition time from ∼6 h to ∼5 min in a real-time imaging scenario.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.