In monitoring patients for drug-induced hearing loss, most audiometric evaluations are limited to the range of frequencies from 0.25 to 8 kHz. However, such testing would fail to detect ototoxicity in patients who have already experienced hearing loss in the ultrahigh frequencies from 10 to 20 kHz. Awareness of ultrahigh-frequency ototoxicity could lead to changes in a drug regimen to prevent further damage. We conducted a prospective study of 105 patients who were receiving a potentially ototoxic drug-either gentamicin, amikacin, or cisplatin-to assess the value of ultrahigh-frequency audiometry in detecting systemic drug-induced hearing loss. We found that expanding audiometry into the ultrahigh-frequency range led to the detection of a substantial number of cases of hearing loss that would have otherwise been missed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.