Laser welding is an innovative method that is frequently used and required by different disciplines and represents a technique of choice in a wide range of applications due to important advantages such as precision, speed, and flexibility. However, the welding method must be used properly otherwise it may deteriorate the mechanical properties of the welded metal and its environment. Therefore, the laser parameters should be precisely determined and carefully applied to the sample. The primary objective of this study was to investigate and propose optimal welding parameters that should be adjusted during the neodymium-doped yttrium aluminum garnet (Nd: YAG)-pulsed laser welding of austenitic stainless steel 316L in an air welding environment by using Argon shielding gas and in wet welding settings in serum medium. The investigation of the welding process in serum medium was conducted in order to propose the most suitable welding parameters being important for future possible medical applications of laser welding in in-vivo settings and thus to investigate the possibilities of the welding process inside the human body. In order to evaluate the quality of welding in air and of wet welding (in serum), a detailed parameter study has been conducted by variation of the laser energy, the welding speed and the focal position. The relationship between the depth of penetration and specific point energy (SPE) was also evaluated. The microstructure of the welded metal was examined by an optical microscope and scanning electron microscope (SEM). Based on the microscopy results, it was found that the largest depth of penetration (1380 µm) was achieved with 19 J laser energy in air medium, while the depth reached the largest value (1240 µm) in serum medium at 28 J laser energy. The increasing energy level showed opposite behavior for air and serum. The results of our study imply that when welding of 316L stainless steel is implemented properly in the body fluid, it would be a promising start for future in-vivo studies.
Ti6Al4V titanium alloys are widely used in a variety of scientific and industrial fields. Laser beam welding is one of the most effective techniques for the joining of titanium plates. The main objective of this study was to investigate the influence of the most important laser parameters on welding performance of titanium alloy in two different physical environments such as air and water (i.e., serum) media. Specifically, the laser beam welding of 2 mm thick Ti6Al4V samples was applied using an Nd:YAG laser in open-air welding using argon as a shielding gas, and in wet welding using a serum environment. The deepest penetration was achieved at −3 mm focal position with 11 J of laser energy in both investigated media (i.e., air and serum). The maximum hardness (1130 HV) was achieved for the focal position of −4 mm in serum medium while it was 795 HV for a focal position of −5 mm in air medium. The minimum (1200 μm and 800 μm) and maximum (1960 μm and 1900 μm) weld widths were observed for air and serum medium, respectively. After the welding process, martensite, massif martensite, and transformed martensite were observed in the microstructure of Ti6Al4V. To the best of our knowledge, the underwater wet welding of titanium alloy was carried out and reported for the first time in this study.
Disposable sterile needles are essential highly consumed medical tools. Medical needles are usually manufactured according to standardized protocols, which currently do not provide the specified minimum tolerance value of the penetration force which strongly depends on needle dimensions, needle cutting edge angle, and the type of the tissue surface to be penetrated. In the present study, experimental measurements were performed according to the ISO 7864 standard to investigate the needle-surface penetration effect via the experimental assessment of the influence of the needle dimensions, cutting edge angle, and three different types of biomedical textiles/artificial tissues (i.e. polyurethane (PU), polypropylene (PP), and artificial leather (AL)) on the penetration force. The results indicate that the smaller the needle's cutting-edge angle, the smaller the penetration force across the target tissue surface. An exponential decaying relationship has been found between the penetration force and the needle diameter/gauge. The results also show that PP provides similar results to other materials that are already included in ISO 7864, and it has a good potential to be accepted as a standardized biomedical textile.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.