The effects of compressive force and the addition of conductive fillers on ultracapacitor electrode performance measurements were studied. We have shown that the force exerted by typical battery coin cell components is inadequate, resulting in erroneous measurements of electrode performance. We further demonstrated that with modest modifications, coin cell measurements can equal those of specialized test fixtures and of packaged cells.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.