Pure parahydrogen (pH(2) ) is the prerequisite for optimal pH(2) -based hyperpolarization experiments, promising approaches to access the hidden orders of magnitude of MR signals. pH(2) production on-site in medical research centers is vital for the proliferation of these technologies in the life sciences. However, previously suggested designs do not meet our requirements for safety or production performance (flow rate, pressure or enrichment). In this article, we present the safety concept, design and installation of a pH(2) converter, operated in a clinical setting. The apparatus produces a continuous flow of four standard liters per minute of ≈98% enriched pH(2) at a pressure maximum of 50 bar. The entire production cycle, including cleaning and cooling to 25 K, takes less than 5 h, only ≈45 min of which are required for actual pH(2) conversion. A fast and simple quantification procedure is described. The lifetimes of pH(2) in a glass vial and aluminum storage cylinder are measured to be T(1C) (glass vial) =822 ± 29 min and T(1C) (Al cylinder) =129 ± 36 days, thus providing sufficiently long storage intervals and allowing the application of pH(2) on demand. A dependence of line width on pH(2) enrichment is observed. As examples, (1) H hyperpolarization of pyridine and (13) C hyperpolarization of hydroxyethylpropionate are presented.
Direct detection of thermal and hyperpolarized (1)H-MR signal in a single acquisition and accurate spin manipulations at 1.8 and 5.5 mT were successfully demonstrated.
The purpose of this work was to analyze the intrinsic diffusion sensitivity of the balanced steady-state free precession (bSSFP) imaging sequence, meaning the observation of diffusion-induced attenuation of the bSSFP steady-state signal due to the imaging gradients. Although these diffusion effects are usually neglected for most clinical gradient systems, such strong gradient systems are employed for high resolution imaging of small animals or MR Microscopy. The impact on the bSSFP signal of the imaging gradients characterized by their b-values was analyzed with simulations and experiments at a 7T animal scanner using a gradient system with maximum gradient amplitude of approx. 700 mT/m. It was found that the readout gradients have a stronger impact on the attenuation than the phase encoding gradients. Also, as the PE gradients are varying with each repetition interval, the diffusion effects induce strong modulations of the bSSFP signal over the sequence repetition cycles depending on the phase encoding gradient table. It is shown that a signal gain can be obtained through a change of flip angle as a new optimal flip angle maximizing the signal can be defined. The dependency of the diffusion effects on relaxation times and b-values were explored with simulations. The attenuation increases with T2. In conclusion, diffusion attenuation of the bSSFP signal becomes significant for high resolution imaging voxel size (roughly < 100 μm) of long T2 substances.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.