The objective of this study was to bench-test provisional bifurcation stenting strategies to provide insights on how best to perform these with drug-eluting stents (DESs). Bifurcation stenting with DESs reduces restenosis compared with bare metal stents (BMSs). Outcomes with a single DES are better than with two DESs but if the main branch is stented, there needs to be a reliable strategy for provisionally stenting the side-branch with full ostial scaffolding and drug application. Stents were photographed in a phantom after deployment with different strategies. With provisional T-stenting, placement of the side-branch stent without gaps is difficult. The internal (or reverse) crush strategy fully scaffolds the side-branch ostium but is experimental. The culotte technique providing excellent side-branch ostial coverage is easier to perform with open-cell or large-cell stent design. In general, kissing balloon post-dilation improves stent expansion, especially at the ostium, and corrects distortion. However, a main-branch kissing balloon of smaller diameter than the deploying balloon causes distortion. Final main-branch postdilatation or sequential postdilatation prevents distortion after the internal crush strategy.
Metabolomic profiling is ideally suited for the analysis of cardiac metabolism in healthy and diseased states. Here, we show that systematic discovery of biomarkers of ischemic preconditioning using metabolomics can be translated to potential nanotheranostics. Thirty-three patients underwent percutaneous coronary intervention (PCI) after myocardial infarction. Blood was sampled from catheters in the coronary sinus, aorta and femoral vein before coronary occlusion and 20 minutes after one minute of coronary occlusion. Plasma was analysed using GC-MS metabolomics and iTRAQ LC-MS/MS proteomics. Proteins and metabolites were mapped into the Metacore network database (GeneGo, MI, USA) to establish functional relevance. Expression of 13 proteins was significantly different (p<0.05) as a result of PCI. Included amongst these was CD44, a cell surface marker of reperfusion injury. Thirty-eight metabolites were identified using a targeted approach. Using PCA, 42% of their variance was accounted for by 21 metabolites. Multiple metabolic pathways and potential biomarkers of cardiac ischemia, reperfusion and preconditioning were identified. CD44, a marker of reperfusion injury, and myristic acid, a potential preconditioning agent, were incorporated into a nanotheranostic that may be useful for cardiovascular applications. Integrating biomarker discovery techniques into rationally designed nanoconstructs may lead to improvements in disease-specific diagnosis and treatment.
The aim of the study was to determine the safety and efficacy of a novel femoral artery closure device (StarClose, Abbott Vascular Devices, Redwood City, CA) following percutaneous coronary intervention employing aspirin, heparin, and glycoprotein (GP) IIb/IIIa inhibition. A prospective nonrandomized single-center pilot study of the StarClose device included a subset of patients undergoing percutaneous coronary intervention utilizing GP IIb/IIIa inhibitors. Those that fulfilled the inclusion criteria (age < 80, no periprocedural haematoma, puncture above the superficial femoral and profunda femoralis artery bifurcation, no significant femoral artery disease) underwent closure of the femoral artery puncture site with a StarClose device immediately on completion of the procedure. Time to hemostasis (TTH), bleeding, mobilization, and short-term clinical follow-up data were collected, and an ultrasound scan of the femoral artery was performed 2 weeks later. Twenty-five patients were recruited, of whom 23 underwent percutaneous coronary intervention (PCI). Their mean age was 58 +/- 12 years, 84% were male, and 63% had unstable angina. All were on aspirin 100-150 mg daily and all PCI patients received i.v. heparin 4-10,000 units at commencement of the procedure and clopidogrel 600 mg on completion. Two patients were on a tirofiban infusion and 23 received a double bolus of eptifibatide, each 0.18 mg/kg, separated by 10 min. The procedural success was 100% and device success 23/25 (92%), with 1 failure due to technical error. The median device delivery time was 36 sec (range, 11-178) and median TTH 37 sec (range, 10-509 sec). There were no major adverse events. In 10 patients, a moderate amount of tract ooze required a short period of adjunctive manual compression. Follow-up ultrasound femoral artery scans revealed no compromise of the vessel lumen. Femoral artery closure with the device following coronary angiography and intervention using glycoprotein IIb/IIIa receptor inhibitors is safe and effective. A randomized trial of a larger number of patients is warranted.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.