Purpose: T 1 -Cube (GE HealthCare) is a relatively new 3-dimensional (3D) fast spinecho (FSE)-based magnetic resonance (MR) imaging sequence that uses a variable flip angle to acquire gap-free volume scans. We compared the gadolinium enhancement characteristics of a heterogeneous population of brain tumors imaged by T 1 -Cube and then 3D fast spoiled gradient recall acquisition in steady state (3D FSPGR) 3-tesla MR imaging to identify the superior modality for specific diagnostic purposes.Methods: We examined 61 lesions from 32 patients using the 2 sequences after administration of gadopentetic acid (Gd-DTPA; 0.1 mmol/kg). Two neuroradiologists independently measured each lesion twice using a region-of-interest (ROI) method. We measured the contrast-to-noise ratio (CNR), the difference in signal intensity (SI) between the tumor and normal white matter relative to the standard deviation (SD) of the SI within the lesion, for both post-contrast 3D FSPGR and post-contrast T 1 -Cube images of the same tumor and compared modality-specific CNRs for all tumors and in subgroups defined by tumor size, enhancement ratio, and histopathology.Results: The mean CNR was significantly higher on T 1 -Cube images than 3D FSPGR images for the total tumor population (1.85 « 0.97 versus 1.12 « 1.05, P < 0.01) and the histologic types, i.e., metastasis (P < 0.01) and lymphoma (P < 0.05). The difference in CNR was even larger for smaller tumors in the metastatic group (4.95 to 23.5 mm 2 ) (P < 0.01). In contrast, mean CNRs did not differ between modalities for high grade glioma and meningioma.Conclusions: Gadolinium enhancement of brain tumors was generally higher when imaged by T 1 -Cube than 3D FSPGR, and T 1 -Cube with Gd enhancement may be superior to 3D FSPGR for detecting smaller metastatic tumors.
The incidence of severe acute hematological toxicity was significantly higher in this study than in previously reported randomized controlled trials (RCTs), especially in the group of 40 mg/m2 cisplatin. A dose of 30 mg/m2 of cisplatin was considered to be feasible in weekly cisplatin and radiation therapy.
BackgroundPrior studies describe histological and immunohistochemical differences in collagen and proteoglycan content in different meniscal zones. The aim of this study is to evaluate horizontal and vertical zonal differentiation of T1rho and T2 relaxation times of the entire meniscus from volunteers without symptom and imaging abnormality.MethodsTwenty volunteers age between 19 and 38 who have no knee-related clinical symptoms, and no history of prior knee surgeries were enrolled in this study. Two T1rho mapping (b-FFE T1rho and SPGR T1rho) and T2 mapping images were acquired with a 3.0-T MR scanner. Each meniscus was divided manually into superficial and deep zones for horizontal zonal analysis. The anterior and posterior horns of each meniscus were divided manually into white, red-white and red zones for vertical zonal analysis. Zonal differences of average relaxation times among each zone, and both inter- and intra-observer reproducibility were statistically analyzed.ResultsIn horizontal zonal analysis, T1rho relaxation times of the superficial zone tended to be higher than those of the deep zone, and this difference was statistically significant in the medial meniscal segments (84.3 ms vs 76.0 ms on b-FFE, p < 0.0001 and 96.5 ms vs 91.7 ms on SPGR, p = 0.004). In vertical zonal analysis, T1rho relaxation times of the white zone tended to be higher than those of the red zone, and this difference was statistically significant in the posterior horn of the medical meniscus (88.4 ms vs 77.1 ms on b-FFE, p < 0.001 and 104.9 ms vs 96.8 ms on SPGR, p =0.001). Likewise, T2 relaxation times of the superficial zone were significantly higher than those of the deep zone (80.4 ms vs 74.4 ms in the medial meniscus, p = 0.011). T2 relaxation times of the white zone were significantly higher than those of the red zone in the medial meniscus posterior horn (96.8 ms vs 84.3 ms, p < 0.001) and lateral meniscus anterior horn (104.6 ms vs 84.2 ms, p < 0.0001). Inter-class and intra-class correlation coefficients were excellent (>0.74) or good (0.60–0.74) in all meniscal segments on both horizontal and vertical zonal analysis, except for inter-class correlation coefficients of the lateral meniscus on SPGR. Compared with SPGR T1rho images, b-FFE T1rho images demonstrated more significant zonal differentiation with higher inter- and intra-observer reproducibility.ConclusionsThere are zonal differences in T1rho and T2 relaxation times of the normal meniscus.
Ankle arthroscopy carries a lower risk of vascular complications when standard anterolateral and anteromedial portals are used. However, the thickness of the fat pad at the anterior ankle affords little protection for the thin-walled anterior tibial artery, rendering it susceptible to indirect damage during procedures performed on the anterior ankle joint. To our knowledge, only 11 cases of pseudoaneurysm involving the anterior tibial artery after ankle arthroscopy have been described in the literature. Here we reported a rare case of a 19-year-old soccer player who presented with pseudoaneurysm of the anterior tibial artery following ankle arthroscopy using an ankle distraction method and underwent anastomosis for the anterior tibial artery injury. Excessive distraction of the ankle puts the neurovascular structures at greater risk for iatrogenic injury of the anterior tibial artery during ankle arthroscopy. Surgeons should look carefully for postoperative ankle swelling and pain after ankle arthroscopy.
The physiological myocardial uptake showed several patterns. Focal uptake was often seen in patients with cardiac disease, but it did not always indicate an abnormal finding when the accumulation was only on the basal wall.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.