The stability and dynamic performance of the grid-connected converter is greatly affected by the coupling between the phase-locked loop (PLL) and the current loop control under weak grid conditions. The traditional control strategies use PLL to obtain the frequency and phase of the grid, which ignore the influence of the PLL and cannot adapt to weak grid conditions. To address this problem, the control and stability of the LCL-Type grid connected converter without PLL under weak grid conditions are studied in-depth in this paper. Firstly, the digital controlled model of the LCL-Type grid-connected converter with capacitor-current feedback active damping is established, and the stability of the system is analyzed. Then, a control strategy without PLL is proposed. The proposed strategy decomposes the grid voltage signal into instantaneous active and instantaneous reactive components through the αβ frame, which can realize the independent control of active and reactive current by simple calculation. The obtained results show that the strategy avoids the influence of the PLL on the inner loop current, and has the advantages of strong stability and anti-interference ability under weak grid conditions. Finally, simulation and experiment results are provided to verify the validity of theoretical analysis.
Based on a single-phase cascaded H-bridge (CHB) multilevel converter, this paper investigates a control strategy combining power estimation and natural frame control (NFC) with the omission of grid voltage sensors. Besides, this control method, without phase-locked loop (PLL), can meet the continuous operation of the system and also eliminates grid voltage feedforward. First, natural frame control is introduced to derive the implementation process of control strategy without PLL, and the calculation formula of AC reference currents is given. Furthermore, the separate control of active and reactive currents is achieved. Second, the principle of proposed control algorithm is presented, and the sinusoidal voltage unit vector for synchronization can be accurately estimated. Next, considering the errors, the article corrects the method through parameter compensation. In addition, the balanced control method stabilized the DC side voltage of the converter. Finally, the effectiveness of this method is verified by computer simulation and experimental prototype.cascaded H-bridge (CHB), natural frame control (NFC), grid voltage sensors, phase-locked loop (PLL), power estimation
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.