Signal amplification by enzyme labels in enzyme-linked immunosorbent assays (ELISAs) is not sufficient for detecting a low number of bacterial pathogens. It is useful to employ approaches that involve multiple signal amplification such as enzymatic amplification plus redox cycling. An advantageous combination of an enzyme product [for fast electrochemical-chemical-chemical (ECC) redox cycling that involves the product] and an enzyme substrate (for slow side reactions and ECC redox cycling that involve the substrate) has been developed to obtain a low detection limit for E. coli O157:H7 in an electrochemical ELISA that employs redox cycling. In our search for an alkaline phosphatase substrate/product couple that is better than the most common couple of 4-aminophenyl phosphate (APP)/4-aminophenol (AP), we compared five couples: APP/AP, hydroquinone diphosphate (HQDP)/hydroquinone (HQ), L-ascorbic acid 2-phosphate/L-ascorbic acid, 4-amino-1-naphthyl phosphate/4-amino-1-naphthol, and 1-naphthyl phosphate/1-naphthol. In particular, we examined signal-to-background ratios in ECC redox cycling using Ru(NH(3))(6)(3+) and tris(2-carboxyethyl)phosphine as an oxidant and a reductant, respectively. The ECC redox cycling that involves HQ is faster than the cycling that involves AP, whereas the side reactions and ECC redox cycling that involve HQDP are negligible compared to the APP case. These results seem to be due to the fact that the formal potential of HQ is lower than that of AP and that the formal potential of HQDP is higher than that of APP. Enzymatic amplification plus ECC redox cycling based on a HQDP/HQ couple allows us to detect E. coli O157:H7 in a wide range of concentrations from 10(3) to 10(8) colony-forming units/mL.
Washing processes, essential in most heterogeneous labeled assays, have been a big hurdle in simplifying the detection procedure and reducing assay time. Nevertheless, less attention has been paid to washing-free heterogeneous labeled assays. We report a purely washing-free immunosensor that allows fast, sensitive, and single-step detection of prostate-specific antigen in serum with low interference. Proximity-dependent electron mediation of ferrocenemethanol (Fc) between an indium-tin oxide (ITO) electrode and a glucose-oxidase (GOx) label allows us to discriminate between a bound and an unbound label: a bound label offers faster electron mediation than an unbound one. The electrooxidation of Fc at a low applied potential (0.13 V vs Ag/AgCl) and a low electrocatalytic ITO electrode and the oxidation of l-ascorbic acid by l-ascorbate oxidase minimize the effect of the interfering species. With a high concentration of glucose (200 mM), the signal and background levels are hardly dependent on the glucose-concentration variation in the sample. The washing-free immunosensor can detect a concentration of ca. 1 pg/mL for mouse IgG in phosphate-buffered saline and a concentration of ca. 10 pg/mL for prostate-specific antigen spiked in female serum after an incubation period of 10 min. The concentrations measured with actual clinical serum samples are in good agreement with the concentrations measured with a commercial instrument, which renders the washing-free heterogeneous immunosensor appealing for practical use.
Stress light up! Methyl thio‐BODIPY 2 detects hypochlorous acid on the basis of the selective oxidation of its methylthioether group into the corresponding sulfoxide by the analyte, resulting in a strong fluorescence turn‐on signal.
We have presented a fluorescent probe 1 that exhibits a fluorescence turn-on signal upon reaction with tyrosinase, and we show that it is readily employed for the assessment of tyrosinase activity and tyrosinase inhibitor activity in buffered aqueous solution, and further utilized for the visualization of endogenous tyrosinase activity in living melanoma cells.
Point-of-care testing (POCT) of biomarkers in clinical samples is of great importance for rapid and cost-effective diagnosis. However, it is extremely challenging to develop an electrochemical POCT technique retaining both ultrasensitivity and simplicity. We report an interference-free electrochemical lateral-flow immunoassay that enables one-step ultrasensitive detection with serum. The electrochemical-chemical-chemical (ECC) redox cycling combined with an enzymatic reaction of an enzyme label is used to obtain high signal amplification. The ECC redox cycling involving Ru(NH3)6(3+), enzyme product, and tris(3-carboxyethyl)phosphine (TCEP) depends on pH, because the formal potentials of an enzyme product and TCEP increase with decreasing pH although that of Ru(NH3)6(3+) is pH-independent. With consideration of the pH dependence of ECC redox cycling, a noble combination of enzyme label, substrate, and product [β-galactosidase, 4-amino-1-naphthyl β-D-galactopyranoside, and 4-amino-1-naphthol, respectively] is introduced to ensure fast and selective ECC redox cycling of the enzyme product along with a low background level. The selective ECC redox cycling at a low applied potential (0.05 V vs. Ag/AgCl) minimizes the interference effect of electroactive species (L-ascorbic acid, acetaminophen, and uric acid) in serum. A detection limit of 0.1 pg mL(-1) for troponin I is obtained only 11 min after serum dropping without the use of an additional solution. Moreover, the lateral-flow immunoassay is applicable to the analysis of real clinical samples.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.