Approach for in vivo real-time assessment of tumor tissue extracellular pH (pHe), redox, and intracellular glutathione based on L-band EPR spectroscopy using dual function pH and redox nitroxide probe and disulfide nitroxide biradical, is described. These parameters were monitored in PyMT mice bearing breast cancer tumors during treatment with granulocyte macrophage colony-stimulating factor. It was observed that tumor pHe is about 0.4 pH units lower than that in normal mammary gland tissue. Treatment with granulocyte macrophage colony-stimulating factor decreased the value of pHe by 0.3 units compared with PBS control treatment. Tumor tissue reducing capacity and intracellular glutathione were elevated compared with normal mammary gland tissue. Granulocyte macrophage colony-stimulating factor treatment resulted in a decrease of the tumor tissue reducing capacity and intracellular glutathione content. In addition to spectroscopic studies, pHe mapping was performed using recently proposed variable frequency proton–electron double-resonance imaging. The pH mapping superimposed with MRI image supports probe localization in mammary gland/tumor tissue, shows high heterogeneity of tumor tissue pHe and a difference of about 0.4 pH units between average pHe values in tumor and normal mammary gland. In summary, the developed multifunctional approach allows for in vivo, noninvasive pHe, extracellular redox, and intracellular glutathione content monitoring during investigation of various therapeutic strategies for solid tumors. Magn Reson Med 000:000–000, 2011.
A variable radio frequency proton–electron double-resonance imaging (VRF PEDRI) approach for pH mapping of aqueous samples has been recently developed (Efimova et al. J. Magn. Reson. 2011, 209, 227–232). A pH map is extracted from two PEDRI acquisitions performed at electron paramagnetic resonance (EPR) frequencies of protonated and unprotonated forms of a pH-sensitive probe. To translate VRF PEDRI to an in vivo setting, an advanced pH probe was synthesized. Probe deuteration resulted in a narrow spectral line of 1.2 G compared to a nondeuterated analogue line width of 2.1 G allowing for an increase of Overhauser enhancements and reduction in rf power deposition. Binding of the probe to the cell-impermeable tripeptide, glutathione (GSH), allows for targeting to extracellular tissue space for monitoring extracellular tumor acidosis, a prognostic factor in tumor pathophysiology. The probe demonstrated pH sensitivity in the 5.8–7.8 range, optimum for measurement of acidic extracellular tumor pH (pHe). In vivo VRF PEDRI was performed on Met-1 tumor-bearing mice. Compared to normal mammary glands with a neutral mean pHe (7.1 ± 0.1), we observed broader pH distribution with acidic mean pHe (6.8 ± 0.1) in tumor tissue. In summary, VRF PEDRI in combination with a newly developed pH probe provides an analytical approach for spatially resolved noninvasive pHe monitoring, in vivo.
Proton electron double resonance imaging (PEDRI) uses the Overhauser effect to image the distribution of free-radicals in biological samples and animals. Standard MRI hardware and software is used, with the addition of hardware to irradiate the free-radical-of-interest's EPR resonance. For in vivo applications it must be implemented at a sufficiently low magnetic field to result in an EPR irradiation frequency that will penetrate the sample but will not cause excessive nonresonant power deposition therein. Many clinical MRI systems use resistive magnets that are capable of operating at 10 -20 mT, and which could thus be used as PEDRI imagers with the addition of a small amount of extra hardware. This article describes the conversion of a 0.38 T whole-body MRI system for operation as a 20.1 mT small-animal PEDRI imager. The magnet power supply control electronics required a small modification to operate at the lower field strength, but no permanent hardware changes to the MRI console were necessary, and no software modification was required. Frequency down-and up-conversion was used on the NMR RF system, together with a new NMR/EPR dual-resonance RF coil assembly. The system was tested on phantoms containing free-radical solution, and was also used to image the distribution of a free-radical contrast agent injected intravenously into anesthetized mice. Proton electron double resonance imaging (PEDRI) (also known as Overhauser imaging) is a method of imaging free-radicals in biological samples. It offers good sensitivity and high spatial resolution independent of the EPR linewidth of the free-radical under study (1). PEDRI is based on the Overhauser effect, wherein EPR resonance of the free-radical under study is irradiated during the acquisition of an MR image. Transfer of polarization from unpaired electron spins to coupled proton spins results in an enhancement of the NMR signal in regions of the sample containing free-radical, revealing its spatial distribution in the final image. PEDRI has been used by a number of research groups to image free-radicals in vivo (2-5), and it is now recognized as a useful alternative to conventional EPR imaging for studying free-radicals in biological systems. Since the EPR linewidth of free-radical probes is strongly dependent on the concentration of dissolved oxygen, PEDRI can be used to measure and image oxygen concentration (1,5,6). PEDRI offers a reliable method of imaging oxygen concentration in vivo (9), particularly when used with single-line free-radical contrast agents (7,8). This capability can enable the detection of tissue hypoxia or ischemia in animal models of disease, and (potentially) in clinical applications. Important applications of this oximetry technique include imaging of oxygenation, in the heart during myocardial ischemia, and in tumors as a function of radiation or other treatment.Although a number of research groups are now using PEDRI, its widespread use has been limited by a lack of commercially-available equipment. However, a resistivemagnet MRI sy...
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.