The ATCM for CT of the abdomen and pelvis substantially reduced radiation dose while maintaining diagnostic image quality. Patients with lower BMI showed more reduction in radiation dose.
The purpose of this study was to evaluate the diagnostic accuracy of patent with ductus arteriosus (PDA) based on the availability of pretest information on routine chest CT with 3 mm slice-thickness. We retrospectively evaluated CT of 64 patients with PDA. The enrolled patients were categorized as group 1 (presence of pretest information) and 2 (absence of pretest information, silent PDA). CTs were read by eleven board-certified radiologists, and subsequently by two blind readers. We investigated whether a PDA was mentioned on the initial CT reading. Correct diagnosis of PDA was made in all patients with group 1 (n = 42). In contrast, only 13.7% were correctly diagnosed in group 2. All cases of missed PDA in group 2 were also missed by two blind readers. It is important to realize that the diagnostic accuracy of silent PDA is poor on the chest CT with 3 mm slice-thickness. Thus, use of axial CT images with the thinnest slice-thickness and multi-planar reformatted images (i.e., sagittal and coronal images) may be one way to reduce the number of missed PDA.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.