Background and Aims Gastric peroral endoscopic myotomy (G-POEM) has been regarded as a novel and minimally invasive therapy for refractory gastroparesis. This study reports the long-term outcomes and possible predictive factors for successful outcomes after G-POEM in an Asian population. Methods This is a retrospective single-centre study of 16 patients who underwent G-POEM for refractory gastroparesis from August 2016 to October 2017. This study included 11 males and 5 females; in addition, 13 patients had postsurgical gastroparesis, and 3 patients had diabetes. The patients included had severe and refractory gastroparesis, as indicated by a Gastroparesis Cardinal Symptom Index (GCSI) score ≥20, and evidence of a delay on gastric emptying scintigraphy (GES). The primary outcome parameter was an assessment of the long-term clinical efficacy of the procedure. The secondary outcome parameter was the detection of possible predictive factors for success and the determination of cut-off values for such predictors. Results Technical success was achieved in 100% of the patients, with a mean procedure time of 45.25±12.96 min. The long-term clinical response was assessed in all patients during a median follow-up of 14.5 months. Clinical success was achieved in 13 (81.25%) patients. There was a significant reduction in the GCSI scores and GES values after the procedure compared to the baseline values, with P values of <0.0001 and 0.012, respectively. Univariate regression analysis showed that the GCSI and GES had significant associations with the future clinical outcomes of the patients, but this finding was not confirmed in multivariate analysis. A GCSI cut-off score of ≤30 had a high sensitivity and a negative predictive value (NPV) of 100% for predicting a successful procedure. GES (half emptying time ≤221.6 min and 2-hour retention ≤78.6%) had a high specificity and a positive predictive value (PPV) of 100%. Conclusions G-POEM is a safe and effective treatment option with a long-term efficacy of 81.6%. GCSI and GES could serve as good predictive measures.
AIMTo evaluate the accuracy of the elastography score combined to the strain ratio in the diagnosis of solid pancreatic lesions (SPL).METHODSA total of 172 patients with SPL identified by endoscopic ultrasound were enrolled in the study to evaluate the efficacy of elastography and strain ratio in differentiating malignant from benign lesions. The semi quantitative score of elastography was represented by the strain ratio method. Two areas were selected, area (A) representing the region of interest and area (B) representing the normal area. Area (B) was then divided by area (A). Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy were calculated by comparing diagnoses made by elastography, strain ratio and final diagnoses.RESULTSSPL were shown to be benign in 49 patients and malignant in 123 patients. Elastography alone had a sensitivity of 99%, a specificity of 63%, and an accuracy of 88%, a PPV of 87% and an NPV of 96%. The best cut-off level of strain ratio to obtain the maximal area under the curve was 7.8 with a sensitivity of 92%, specificity of 77%, PPV of 91%, NPV of 80% and an accuracy of 88%. Another estimated cut off strain ratio level of 3.8 had a higher sensitivity of 99% and NPV of 96%, but with less specificity, PPV and accuracy 53%, 84% and 86%, respectively. Adding both elastography to strain ratio resulted in a sensitivity of 98%, specificity of 77%, PPV of 91%, NPV of 95% and accuracy of 92% for the diagnosis of SPL.CONCLUSIONCombining elastography to strain ratio increases the accuracy of the differentiation of benign from malignant SPL.
Evaluating the role of endoscopic ultrasound (EUS) elastography and strain ratio in differentiation between malignant and benign pancreatic lesions.Three hundred twenty-five patients with solid pancreatic lesions were enrolled in this prospective study from 2014 to 2017. EUS real-time elastography scoring and strain ratio were done to all patients and compared to the final diagnosis to assess its sensitivity, specificity, positive and negative predictive values (PPV and NPV) in differentiating malignant from benign lesions.A cut-off value of 4.2 we had sensitivity of 95%, specificity of 63%, PPV of 89%, NPV of 81%, and accuracy of 87%. Another cut-off value of 10.9 showed a sensitivity of 75%, specificity of 88%, PPV of 95%, NPV of 54%, and accuracy of 79%. Adding the elastography to the better cut-off value gave a sensitivity of 97%, specificity of 63%, PPV of 89%, NPV of 88%, and accuracy of 89%.Real-time elastography and strain ration are valuable in differentiating malignant from pancreatic lesions.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.