We measured viscoelasticity of two nanoscale systems, single protein molecules and molecular layers of water confined between solid walls. In order to quantify the viscoelastic response of these nanoscale systems in liquid environment, the measurements are performed using two types of atomic force microscopes (AFMs), which employ different detection schemes to measure the cantilever response. We used a deflection detection scheme, available in commercial AFMs, that measures cantilever bending and a fibre-interferometer based detection which measures cantilever displacement. The hydrodynamics of the cantilever is modelled using Euler–Bernoulli equation with appropriate boundary conditions which accommodate both detection schemes. In a direct contradiction with many reports in the literature, the dissipation coefficient of a single octomer of titin I278 is found to be immeasurably low. The upper bound on the dissipation coefficient is 5 × 10−7 kg s−1, which is much lower than the reported values. The entropic stiffness of single unfolded domains of protein measured using both methods is in the range of 10 mN m−1. We show that in a conventional deflection detection measurement, the phase of the bending signal can be a primary source of artefacts in the dissipation estimates. It is recognized that the measurement of cantilever displacement, which has negligibly small phase lag due to hydrodynamics of the cantilever at low excitation frequencies, is better suited for ensuring artefact-free measurement of viscoelasticity compared to the measurement of the cantilever bending. Further, it was possible to measure dissipation in molecular layers of water confined between the tip and the substrate using fibre interferometer based AFM with similar experimental parameters. It confirms that the dissipation coefficient of a single I278 is below the detection limit of AFM. The results shed light on the discrepancy observed in the measured diffusional dynamics of protein collapse measured using Force spectroscopic techniques and single-molecule optical techniques.
Surface coatings play an important role in improving the performance of biomedical implants. Polydimethylsiloxane (PDMS) is a commonly used material for biomedical implants, and surface-coated PDMS implants frequently face problems such as delamination or cracking of the coating. In this work, we have measured the performance of nano-coatings of the biocompatible protein polymer silk fibroin (SF) on pristine as well as modified PDMS surfaces. The PDMS surfaces have been modified using oxygen plasma treatment and 3-amino-propyl-triethoxy-silane (APTES) treatment. Although these techniques of PDMS modification have been known, their effects on adhesion of SF nano-coatings have not been studied. Interestingly, testing of the coated samples using a bulk technique such as tensile and bending deformation showed that the SF nano-coating exhibits improved crack resistance when the PDMS surface has been modified using APTES treatment as compared to an oxygen plasma treatment. These results were validated at the microscopic and mesoscopic length scales through nano-scratch and nano-indentation measurements. Further, we developed a unique method using modified atomic force microscopy to measure the adhesive energy between treated PDMS surfaces and SF molecules. These measurements indicated that the adhesive strength of PDMS-APTES-SF is 10 times more compared to PDMS-O2-SF due to the higher number of molecular linkages formed in this nanoscale contact. This lower number of molecular linkages in the PDMS-O2 indicates that only fewer numbers of surface hydroxyl groups interact with the SF protein through secondary interactions such as hydrogen bonding. On the other hand, a larger number of amine groups present on PDMS-APTES surface hydrogen bond with the polar amino acids present on the silk fibroin protein chain, resulting in better adhesion. Thus, APTES modification to the PDMS substrate results in improved adhesion of nano-coating to the substrate and enhances the delamination and crack resistance of the nano-coatings.
The quantitative measurement of viscoelasticity of nano-scale entities is an important goal of nanotechnology research and there is considerable progress with advent of dynamic atomic force microscopy. The hydrodynamics of cantilever, the force sensor in AFM measurements, plays a pivotal role in quantitative estimates of nano-scale viscoelasticity. The point-mass (PM) model, wherein the AFM cantilever is approximated as a point-mass with mass-less spring is widely used in dynamic AFM analysis and its validity, particularly in liquid environments, is debated. It is suggested that the cantilever must be treated as a continuous rectangular beam to obtain accurate estimates of nano-scale viscoelasticity of materials it is probing. Here, we derived equations, which relate stiffness and damping coefficient of the material under investigation to measured parameters, by approximating cantilever as a point-mass and also considering the full geometric details. These equations are derived for both tip-excited as well as base-excited cantilevers. We have performed off-resonance dynamic atomic force spectroscopy on a single protein molecule to investigate the validity of widely used PM model. We performed measurements with AFMs equipped with different cantilever excitation methods as well as detection schemes to measure cantilever response. The data was analyzed using both, continuous beam model and the PM model. We found that both models yield same results when the experiments are performed in truly off-resonance regime with small amplitudes and the cantilever stiffness is much higher than the interaction stiffness. Our findings suggest that a simple PM approximation based model is adequate to describe the dynamics, provided care is taken while performing experiments so that the approximations used in these models are valid.
The nanomechanical response of a folded single protein, the natural nanomachine responsible for myriad biological processes, provides insight into its function. The conformational flexibility of a folded state, characterized by its viscoelasticity, allows proteins to adopt different shapes to perform their function. Despite efforts, its direct measurement has not been possible so far. We present a direct and simultaneous measurement of the stiffness and internal friction of the folded domains of the protein titin using a special interferometer based atomic force microscope. We analyzed the data by carefully separating different contributions affecting the response of the experimental probe to obtain the folded state’s viscoelasticity. Above ∼95 pN of force, the individual immunoglobulins of titin transition from an elastic solid-like native state to a soft viscoelastic intermediate.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.