The variable source OGLE-UCXB-01 is the first OGLE-discovered ultracompact X-ray binary (UCXB). The 12 yr long-term OGLE optical photometry of this source shows a period of P = 12.8 min and a fast period-decreasing rate P ̇ = − 9.2 × 10 − 11 s s−1. At a luminosity of L X ≈ 4 × 10 33 erg s−1, its X-ray emission is also variable and correlated with the optical variability. To determine the nature of this variable source, specifically the masses and types of its binary components, we first consider an attractive possibility that the optical variation is due to the secondary’s ellipsoidal variation and a strong gravitational wave emission drives the orbital decay. However, we cannot find an allowable solution to the secondary that simultaneously satisfies the three constraints: an ultratight orbit, the bright absolute magnitude, and the large-amplitude brightness variation. Moreover, the inferred mass-transfer rate is too high. This scenario is therefore ruled out. We then find the system is fully consistent with an “intermediate polar” model, in which the optical and X-ray emission comes from a magnetized white dwarf (WD) accreting from a low-mass (≲ 0.7 M ⊙ ) main-sequence secondary. The observed period decay is the accretion-driven spin-up of the WD. The WD spin period is 12.8 minutes and the orbital period is shorter than 10 hr. The method presented here can be applied to other UCXB candidates or impostors with only time-domain data available.
We report the development of an ultralow-noise bipolar current source based on the configuration of H-bridge current switching. The measured relative current noise fluctuation reaches 4 × 10−9 Hz−1/2, which enables an ultra-stable magnetic system for cold atom experiments. We avoid the influence of the AC leakage currents induced by the large parasitic capacitance of the H-bridge. First, the current sensor is placed as close as possible to the magnetic coils so that the systematic errors from these leakage currents are minimized. Second, the large parasitic capacitance, which parallels the magnetic coils and forms an LC oscillator, is removed from the feedback loop in our setup to maintain a large self-resonance frequency of the feedback control loop. These two improvements lead to a current source that is more precise and less noisy. Remarkably, the lowest current noise density produced by the proposed method is only 500 nA Hz−1/2 at a current of 100 A, which is about ten fold smaller than the case with leakage current. To optimize the feedback control, a numerical simulation is implemented by using Matlab Simulink, and the numerical simulation results are entirely consistent with the experimental results.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.