Background The elevated D-dimer value is one of the clues used to diagnose acute aortic dissection (AAD), but the rapid D-dimer assay is not used at all emergency hospitals. The fibrinogen/fibrin degradation products (FDP) value is also an indicator of enhanced fibrinolysis and may therefore be a useful marker in patients with AAD. In addition, the association between FDP values and partial thrombosis of the false lumen is not elucidated. Patients The present study enrolled 50 patients (66.5±11.2 years of age; median, 66.5 years of age, male subjects comprised 60.0% of the series) with AAD who were admitted to the hospital between July 2005 and December 2007 and 57 patients with acute myocardial infarction (AMI; 70.8±10.4 years of age; median, 71.0 years of age, male subjects comprised 71.9% of the current series) served as a control group. Results The FDP values (μg/mL) in patients with AAD were significantly higher than those of AMI patients (40.2±78.6; median, 14.7 vs. 5.2±9.8; median, 1.7, p<0.001). A receiver operating characteristic curves analysis showed that an elevated FDP level (2.05 μg/mL) was predictive of a diagnosis of AAD with a sensitivity and specificity of 98% and 54%, respectively. The FDP levels of patients (n=14) who had partial thrombosis of the false lumen were significantly higher than in discharged patients without a surgical repair (n=21) who had a patent or complete thrombosis of the false lumen (35.8±43.2; median, 18.8 vs. 14.0±21.3; median, 5.5, p=0.01). Conclusion The measurement of FDP may therefore be useful for the initial assessment of patients with suspected AAD and in the prediction of thrombotic status of the false lumen.
This study suggests that the LV diastolic indexes as determined by 3D echocardiography provide useful information in the clinical assessment of the diastolic LV function.
Although the study group is small, about two-thirds of DES thrombi in late and very late ST were days or weeks old. These findings suggest an important discrepancy between the time of onset of the intra-stent thrombotic process and the occurrence of acute clinical symptoms, and provide further information about another potential mechanism of DES thrombosis.
The initial medical management for select patients with a thrombosed false lumen in the ascending aorta was a safe and feasible strategy in real-world practice.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.