This paper presents a modified model for hand–eye calibration based on dual quaternion algebra. By using dual quaternions to represent the rotations and translations of a rigid body simultaneously in the task space, the formulation is elegant for the analysis of the hand–eye equation. The hand–eye transformation derived in this study is represented in a compact manner, which uses a combination of the dual part and the real part of the dual quaternion. Although the hand–eye equation can be solved by using six elements of a dual quaternion without using its scalar parts, the scaler numbers in both the real and dual parts of a dual quaternion contain part of the pose information. The originality is based on the derivation of the construct of the identification algorithm of external parameters of the camera by using all eight elements of a dual quaternion. Then, the data transformation between the cameras of the dual-arm hand–eye robot system is presented. The corresponding results demonstrate that the proposed hand–eye calibration algorithm can process measurement data with noise and can also improve the identification accuracy to verify its efficiency.
Purpose The purpose of this paper is to propose a control algorithm to improve the backdrivability performance of minimally invasive surgical robotic arms, so that precise manual manipulations of robotic arms can be performed in the preoperative operation. Design/methodology/approach First, the flexible-joint dynamic model of the 3-degree of freedom remote center motion (RCM) mechanisms of minimally invasive surgery (MIS) robot is derived and its dynamic parameters and friction parameters are identified. Next, the angular velocities and angular accelerations of joints are estimated in real time by the designed Kalman filter. Finally, a control algorithm based on Kalman filter is proposed to enhance the backdrivability of RCM mechanisms by compensating for the internally generated gravitational, frictional and inertial resistances experienced during the positioning and orientating. Findings The parameter identification for RCM mechanisms can be experimentally evaluated from comparison between the measured torques and the reconstructed torques. The accuracy and convergence of the real-time estimation of angular velocity and acceleration of the joint by the designed Kalman filter can be verified from corresponding simulation experiments. Manual adjustment experiments and animal experiments validate the effectiveness of the proposed backdrivability control algorithm. Research limitations/implications The backdrivability control algorithm presented in this paper is a universal method to enhance the manual operation performance of robots, which can be used not only in the medical robot preoperative manual manipulation but also in robot haptic interaction, industrial robot direct teaching and active rehabilitation training of rehabilitation robot and so on. Originality/value Compared with other backdrivability design methods, the proposed algorithm achieves good backdrivability for RCM mechanisms without using force sensors and accelerometers. In addition, this paper presents a new static friction compensation approach for a joint moving with very low velocity.
This study focuses on a robot vision localization method for coping with the operational task of automatic nasal swab sampling. The application is important in the detection and epidemic prevention of Corona Virus Disease 2019 (COVID-19) to alleviate the large-scale negative impact of individuals suffering from pneumonia owing to COVID-19. In this method, the idea of a hierarchical decision network is used to consider the strong infectious characteristics of the COVID-19, which is followed by processing the robot behavior constraint condition. The visual navigation and positioning method using a single-arm robot for sampling is also planned, which considers the operation characteristics of medical staff. In the decision network, the risk factor for potential contact infection caused by swab sampling operations is established to avoid the spread among personnel. A robot visual servo control with artificial intelligence characteristics is developed to achieve a stable and safe nasal swab sampling operation. Experiments demonstrate that the proposed method can achieve good vision positioning for the robots and provide technical support for managing new major public health situations.
Being the most important component of minimally invasive surgical robot system, remote centre mechanisms (RCM) composed of three joints, achieve the position and orientation adjustment of the surgical instrument inside a patient's body. In order to implement the high-precision position control and eliminate the adverse effect result from the friction of RCM's joints, in this paper, a fuzzy sliding mode controller with the friction compensation is designed. The result of simulation and experiment show that the controller designed can provide a trajectory tracking with real-time, high-precision performance and strong robustness.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.