• TAVI-planning CT using variable helical pitch (VHP) scanning is useful. • The average volume of contrast material was 38.7 ± 8.5 mL. • The average attenuations of all the arteries were >400 HU. • This CT had a high sensitivity and NPV for excluding obstructive CAD.
Purpose:To assess the clinical importance in the feature change in giant cell tumors of the bone (GCTB) after denosumab treatment, detected by MRI.Methods:In 12 patients, MRI and CT of GCTB obtained before and after the treatment retrospectively compared. The tumor size, the signal intensity (SI) ratio between the solid part of the GCTB and muscle, cystic part size, gadolinium enhancement and apparent diffusion coefficient (ADC) value were measured on MRI. The bone formation in the tumor was observed on CT and X-ray.Results:The mean number of denosumab injections was 19 ± 10. The follow-up period was up to 2 years. One case showed partial remission, while the other 11 cases were stable. A mean SI ratio on T2-weighted image statistically significantly decreased from 3.9 to 1.9 after the treatment. A cystic component in the tumor was observed in five cases before the treatment, and the diameter of the cystic part decreased after the treatment in 80% of cases (4/5). All the tumors showed contrast enhancement on T1-weighted image pre- and post-treatment (11/11). The averaged ADC values were 1.52 × 10−3 mm2/s before and 1.44 × 10−3 mm2/s after the treatment (P = 0.63). Bone formation in the tumor was observed in 58% of cases (7/12).Conclusion:The decrease of SI ratio on T2-weighted image, shrinkage of cystic part and bone formation should be regarded as the effectiveness of denosumab treatment despite of no substantial change in the tumor size.
No clinical studies to date have compared the airway luminal area between supine and standing positions. Our aim was therefore to compare the airway luminal area between these two positions on computed tomography (CT) and to determine its correlation with forced expiratory volume in 1 s (FEV1). Thirty-two asymptomatic volunteers underwent both conventional (supine position) and upright (standing position) CT during deep inspiration breath-holding. Pulmonary function tests were conducted on the same day. We measured the airway luminal area on CT in each position. Paired t-tests and Pearson's correlation coefficients were used for statistical analysis. The average luminal areas of the trachea, right and left main bronchi, and average third-generation airway were greater in the standing than the supine position by 3.4%, 6.1%, 5.5%, and 5.2%, respectively. The correlation coefficients between airway luminal areas and FEV1 tended to be higher in the standing than the supine position; this correlation was highest for the average third-generation airway (r = 0.70, P < 0.0001). The airway luminal areas of the trachea, bilateral main bronchi, and average third-generation airway were greater in the standing than the supine position. The average third-generation airway area in the standing position had the highest correlation with FEV1.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.