<p><span>In 1986 a well, which was planned as a convetional production well in the Nesjavellir Field in the Hengill Area, SW Iceland, was unexpectedly drilled into a very hot formation at the depth of 2.1&#160;km. The measured temperature in the lowest part of the well was 380&#176;C, which was the upper range of the measuring tool used. Thus, the bottom-hole temperature was most probably higher. No one expected to hit such a hot body in this place and the well design was not appropriate to handle such high temperatures and resulting pressures. Thus, the lower parts of that well were closed off and it has since then been operated as a conventional geothermal well.</span></p><p><span>This incidence sparked the idea of drilling deeper into volcanic hydrothermal systems in Iceland in order to gain a better understanding of the roots of the geothermal systems and to be able to produce fluids with higher enthalpy. The Iceland Deep Drilling Project (IDDP) is supposed to realize that idea. The IDDP project is a consortium of domestic and international partners, both from industry and academia. The three power companies in Iceland, which operate power-production in volcanic geothermal fields (Landsvirkjun, HS-Orka, OR), committed themselves to drill one deep well each in a field of theirs. </span></p><p><span>To date two wells have been drilled in the IDDP project. The first one, IDDP-1, was drilled in the Krafla Field, N Iceland, which is operated by Landsvirkjun, and the second well, IDDP-2, was drilled in the Reykjanes Field, which is operated by HS-Orka. The original plan was to drill down to 4-5 km. However, the IDDP-1 in Krafla was drilled into magma of rhyolite composition at the depth of 2.1 km and could therefore not be drilled further. During flow tests, it was flowing superheated steam at high pressure at well head temperature of 450&#176;C. The power capacity was estimated to be 36 MW<sub>e</sub>. However, due to hostile chemistry of the fluid and damaged casing, the well had to be abandoned and closed after the well tests. IDDP-2 was drilled down to 4,659 m. The highest temperature measured in the bottom of the well was 426&#176;C at a pressure of 340 bar. It was also possible to obtain core samples from the bottom of the well. However, due to damaged casing it hasn't been possible to do further temperature and pressure measurements in the lower parts of IDDP-2. To date flow tests in IDDP-2 have not started.</span></p><p><span>The next well in the IDDP project is planned in the Hengill Area. The most promising target is the hot body that started it all in the Nesjavellir Field. According to experience from IDDP-1 and IDDP-2 the main techincal obstacle is the casing. Both wells have serious casing problems. The magma body unexpectedly hit by IDDP-1 illustrated that careful interdisciplinary preperations are needed when drilling into the unknown. Currently, few projects are ongoing to fill the knowledge gaps in order to minimize risk and maximize the probability of successful drilling. </span></p>
Non-eruptive uplift and subsidence episodes remain a challenge for monitoring and hazard assessments in active volcanic systems worldwide. Sources of such deformation may relate to processes such as magma inflow and outflow, motion and phase changes of hydrothermal fluids or magma volatiles, heat transfer from magmatic bodies and heat-mining from geothermal extraction. The Hengill area, in southwest Iceland, hosts two active volcanic systems, Hengill and Hrómundartindur, and two high-temperature geothermal power plants, Hellisheiði and Nesjavellir. Using a combination of geodetic data sets (GNSS and InSAR; Global Navigation Satellite Systems and Interferometry Synthetic Aperture Radar, respectively) and a non-linear inversion scheme to estimate the optimal analytical model parameters, we investigate the ground deformation between 2017–2018. Due to other ongoing deformation processes in the area, such as plate motion, subsidence in the two geothermal production fields, and deep-seated source of contraction since 2006, we estimate 2017–2018 difference velocities by subtracting background deformation, determined from data spanning 2015–2017 (InSAR) or 2009–2017 (GNSS). This method highlights changes in ground deformation observed in 2017–2018 compared to prior years: uplift signal of ∼10 km diameter located in the eastern part of the Hengill area, and geothermal production-related temporal changes in deformation near Húsmúli, in the western part of the Hengill area. We find an inflation source located between the Hengill and Hrómundartindur volcanic complexes, lasting for ∼5 months, with a maximum uplift of ∼12 mm. Our model inversions give a source at depth of ∼6–7 km, located approximately in the same crustal volume as an inferred contracting source in 2006–2017, within the local brittle-ductile transition zone. No significant changes were observed in local seismicity, borehole temperatures and pressures during the uplift episode. These transient inflation and deflation sources are located ∼3 km NW from a source of non-eruptive uplift in the area (1993–1999). We consider possible magmatic and hydrothermal processes as the causes for these inflation-deflation episodes and conclude that further geophysical and geological studies are needed to better understand such episodes.
Groundwater is a key resource for safe drinking water supply. Yet unconfined aquifers can be vulnerable to microbial contamination during extreme weather events that lead to surface runoff. The current study characterises the groundwater microbiome of a porous basaltic rock aquifer in South-West Iceland used for drinking water extraction and analyses the microbial community dynamics during surface runoff. The groundwater microbial community sampled from twelve wells across the extraction area contained over 745 prokaryotic genera and was phylogenetically similar between wells and most seasons, representing a diverse but homogenous ecosystem. The largest seasonal variation in the microbial community composition was detected during a period of concurrent snow melt and high precipitation leading to surface runoff. This period was characterised by an increased abundance of soil-associated taxa in the groundwater microbiome and specifically of taxa assigned to Aeromonas and Bacillus. A field experiment simulating high surface runoff around a groundwater well confirmed the increased abundance of surface soil microorganisms in the well water, indicating vulnerability of groundwater towards surface microbial intrusion during extreme weather events. As such events are likely to increase due to climate change, novel water management tools such as microbial community analysis could help ensure drinking water safety.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.