Electronic cigarettes (E-cigarettes) are a potential means of addressing the harm to public health caused by tobacco smoking by offering smokers a less harmful means of receiving nicotine. As e-cigarettes are a relatively new phenomenon, there are limited scientific data on the longer-term health effects of their use. This study describes a robust in vitro method for assessing the cytotoxic response of e-cigarette aerosols that can be effectively compared with conventional cigarette smoke. This was measured using the regulatory accepted Neutral Red Uptake assay modified for air–liquid interface (ALI) exposures. An exposure system, comprising a smoking machine, traditionally used for in vitro tobacco smoke exposure assessments, was adapted for use with e-cigarettes to expose human lung epithelial cells at the ALI. Dosimetric analysis methods using real-time quartz crystal microbalances for mass, and post-exposure chemical analysis for nicotine, were employed to detect/distinguish aerosol dilutions from a reference Kentucky 3R4F cigarette and two commercially available e-cigarettes (Vype eStick and ePen). ePen aerosol induced 97%, 94% and 70% less cytotoxicity than 3R4F cigarette smoke based on matched EC50 values at different dilutions (1:5 vs. 1:153 vol:vol), mass (52.1 vs. 3.1 μg/cm2) and nicotine (0.89 vs. 0.27 μg/cm2), respectively. Test doses where cigarette smoke and e-cigarette aerosol cytotoxicity were observed are comparable with calculated daily doses in consumers. Such experiments could form the basis of a larger package of work including chemical analyses, in vitro toxicology tests and clinical studies, to help assess the safety of current and next generation nicotine and tobacco products.
This study assessed the toxicological and biological responses of aerosols from a novel hybrid tobacco product. Toxicological responses from the hybrid tobacco product were compared to those from a commercially available Tobacco Heating Product (c-THP), a prototype THP (p-THP) and a 3R4F reference cigarette, using in vitro test methods which were outlined as part of a framework to substantiate the risk reduction potential of novel tobacco and nicotine products. Exposure matrices used included total particulate matter (TPM), whole aerosol (WA), and aqueous aerosol extracts (AqE) obtained after machine-puffing the test products under the Health Canada Intense smoking regime. Levels of carbonyls and nicotine in these matrices were measured to understand the aerosol dosimetry of the products. The hybrid tobacco product tested negative across the in vitro assays including mutagenicity, genotoxicity, cytotoxicity, tumour promotion, oxidative stress and endothelial dysfunction. All the THPs tested demonstrated significantly reduced responses in these in vitro assays when compared to 3R4F. The findings suggest these products have the potential for reduced health risks. Further pre-clinical and clinical assessments are required to substantiate the risk reduction of these novel products at individual and population levels.
Objectives
Cigarette smoke aqueous aerosol extracts (AqE) have been used for assessing tobacco products, particularly with in vitro models such as oxidative stress and inflammation. These test articles can be generated easily, but there are no standardised methods for the generation and characterisation or stability. We investigated the effects of pro-oxidant smoke-derived chemicals by using 3R4F AqE generated under standardised conditioning and smoking regimes and assessed the stability over 31-week timeframe. Twenty batches generated from ten puffs per cigarette bubbled through 20 ml cell culture media were used fresh and thawed from frozen aliquots stored at – 80 ºC.
Results
Nicotine levels quantified by gas chromatography/mass spectrometry and optical density at 260 nm showed chemical and physical stability from week 0 (fresh sample) to weeks 1, 4, 8 and 31 (frozen samples). No significant change in H292 human bronchial epithelial cell viability or oxidative stress were observed between fresh AqE at week 0 and frozen AqE at 31 weeks. AqEs generated by our protocol were stable for up to 31 weeks for all tested end points, suggesting that it may not be necessary to use freshly generated AqE for each study, thus reducing batch-to-batch variability.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.