A simple, rapid and sensitive liquid chromatography-tandem mass spectrometric (LC-MS/MS) assay method has been developed and fully validated for the simultaneous quantification of tetrabenazine and its active metabolites α-dihydrotetrabenazine and β-dihydrotetrabenazine in human plasma. Tetrabenazine d7 was used as internal standard (IS). The analytes were extracted from 200 μL aliquots of human plasma via solid-phase extraction using C18 solid-phase extraction cartridges. The reconstituted samples were chromatographed on a Zorbax SB C18 column using a 60:40 (v/v) mixture of acetonitrile and 5 mm ammonium acetate as the mobile phase at a flow rate of 0.8 mL/min. The API-4000 LC-MS/MS in multiple reaction-monitoring mode was used for detection. The calibration curves obtained were linear (r(2) ≥ 0.99) over the concentration range of 0.01-5.03 ng/mL for tetrabenazine and 0.50-100 ng/mL for α-dihydrotetrabenazine and β-dihydrotetrabenazine. Method validation was performed as per Food and Drug Administration guidelines and the results met the acceptance criteria. The method is precise and sensitive enough for its intended purpose. A run time of 2.5 min for each sample made it possible to analyze more than 300 plasma samples per day. The proposed method was found to be applicable to clinical studies.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.