ObjectiveTo investigate the physical and chemical compatibility of pentoxifylline (PTX) with a range of parenteral medications used in neonatal intensive care.DesignPTX and drug solutions were combined in glass vials, inspected for physical incompatibility and evaluated on the basis of PTX concentrations for chemical compatibility.ResultsNo precipitation, colour change or turbidity was observed in any of the test mixtures. The PTX concentration was approximately 5.5% lower when combined with undiluted calcium gluconate injection (100 mg/mL). The PTX concentration ratios for all other combinations, including diluted calcium gluconate injection (50 mg/mL), were in the range of 99.5%–102%.ConclusionIn simulated Y-site conditions, PTX was found to be compatible with 15 parenteral medications and six total parenteral nutrition solutions. Based on PTX concentration tests, it would be prudent to avoid mixing PTX with undiluted calcium gluconate injection.
Plasma paracetamol level is used as a clinical tool for prediction of persons at risk of hepatotoxicity and need for antidote treatment in acute paracetamol poisoning. This facility is unavailable in the National Hospital of Sri Lanka. Therefore tests are done in different laboratories. We calculated trueness and intra-assay and inter-assay variability as a coefficient of variability (CV) in three commercial laboratories (A, B and C) and two academic laboratories (D and E) to determine the reliability of the assay results produced in different laboratories, Trueness is a measure for the closeness of agreement between the true value and the value obtained by applying the test procedure a number of times [1]. It is assessed using samples spiked at least in three different concentration levels (low, medium and high) and is expressed as a percentage [1]. A variation of ±20% at the lowest calibration point and ±15 % for higher concentrations are regarded as acceptable [1]. CV is the standard deviation divided by mean and is expressed as a percentage. A CV less than 20% is considered acceptable [2].The stock solution of paracetamol was prepared in blank plasma. Three clinically relevant strengths (40 mg/l, 75mg/l and 140mg/l) were prepared in blank plasma using the stock sample and were sent for analysis to the five laboratories. All analysts were blinded to the strength of the samples. The procedure was repeated after three days.The assay results of 5 laboratories, percentage deviation, intra-assay and inter-assay variability and cost/per test are shown in the Table. The inter-assay variability ranged widely among all laboratories. However, the paracetamol concentrations obtained at academic laboratories (D and E) were within the trueness limit, intra-assay variability and inter-assay variability. Cost per test was highest at the laboratory C, although the results produced at this laboratory were not within the acceptable trueness limits. Paracetamol concentrations estimated at laboratory B also were not within the limits of trueness and intra-assay variability. Furthermore laboratory B had a very high percentage deviation (1650%) for the low concentration in day 1 which is likely due to a methodological error.The results of this study indicate that there are wide variations in plasma paracetamol concentrations estimated at different laboratories for a given sample. This is unacceptable given that it is critical for both therapeutic decisions and outcome. We conclude that the laboratories should carry out regular calibration of instruments and validation of methods.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.