With the recent rapid growth in transcatheter mitral and tricuspid valve interventions, it has become increasingly important to understand detailed anatomy of the valves. In this study, we investigated the similarities, differences, and associations between the dimensions of the atrioventricular valves in a sheep model, as sheep heart valves have a similar morphology to human valves. A systematic dissection of twenty-five sheep hearts was performed, with annular circumference measurement, and sub-valvular anatomy documentation. There was a significant association (r=0.865; p=0.007) between the circumference of the mitral and tricuspid annuli. Authors also identified significantly more chordae tendinea in the subvalvular mitral apparatus compared to the tricuspid valve (15.8±1.2 vs. 13.9±1.5; p<0.001). In conclusion, there is a significant association between the size of mitral and tricuspid valve annuli, and the morphology of leaflets and subvalvular apparatus is different between the two valves. These findings could have important implications in transcatheter device design, sizing, and optimal intervention timing.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.